Program station volume feature: Difference between revisions
From Zenitel Wiki
No edit summary |
No edit summary |
||
| Line 34: | Line 34: | ||
16 9 | 16 9 | ||
AlphaCom | [[AlphaNet Data Protocol|AlphaCom Data Protocol]] message to change the volume: [[VOL]] | ||
[[AlphaCom Feature List|Back to feature list]] | [[AlphaCom Feature List|Back to feature list]] | ||
Revision as of 08:53, 25 January 2008
| Feature: | Set station volume |
| Default directory number: | 783 |
| Feature number: | 38 |
| Parameter 1: | 0 (N/A) |
| Description: | Set output level (0-9) on ASLT line board. Primarily to compensate for long wires. Dial: 783 + digit 0-9. Default level is 3. |
The ASLT output level can also be set from the Users & Stations menu in AlphaPro. The relation between the 783 volume setting and AlphaPro setting is as follows:
AlphaPro 783+n -------- ----- -14 0 -12 -10 -8 1 -6 -4 2 -2 0 3 (Default) 2 4 4 5 6 6 8 7 10 12 8 14 16 9
AlphaCom Data Protocol message to change the volume: VOL