Difference between revisions of "Open / Private selection feature"
From Zenitel Wiki
(New page: '''80 FEAT_OPEN_PRIVATE''' {| border="1" !style="background:#ffdead;"|Param1 !style="background:#ffdead;"|Description |- | ?? || Toggle functional OPEN/PRIVATE on station |- |colspan="2"|A...) |
|||
Line 1: | Line 1: | ||
+ | {| | ||
+ | |- | ||
+ | |width="170pt"|'''Feature''': | ||
+ | | Follow Me | ||
+ | |- | ||
+ | |'''Default directory number''': || 7886, 7887 | ||
+ | |- | ||
+ | |'''Feature number''': || 80 | ||
+ | |-valign="top | ||
+ | |'''Parameter 1''': || 0 = Open<br> 1= Private | ||
+ | |-valign="top" | ||
+ | |'''Description''': || Feature for activating [[Transfer_Features#Follow_Me|Follow me]] (e.g. remote Call Forwarding) | ||
+ | Procedure: On the remote station, dial 72 + own station number to forward calls to the remote station. | ||
+ | <br><br> | ||
+ | See also: [[Transfer_Features#Call_Forwarding|Call Forwarding]] | ||
+ | |||
+ | |} | ||
+ | Alternative way to select call mode OPEN. | ||
+ | Procedure: Dial 7886. If the feature is allowed, a success tone is heard, else a failure tone. The setting is permanent (stored in NVRAM, survives reset). | ||
+ | Configuration: There is a flag in AlphaPro that decide if this station's OPEN/PRIVATE status is controlled by feature codes OR by station hardware. (User/More../Programmable Open/Private). | ||
+ | Application: | ||
+ | • Fixed functionality often required, where the station must ignore the PRIVATE switch. | ||
+ | • EMC problems with PRIVATE switch in wall stations. Now solved by removing the switch, and use keypad for PRIVATE mode. | ||
+ | Version: AMC 06.00 DirNo: 7886 Feature: 80/0 (Db ref. 587) | ||
+ | 3.1.7. Feature idle: Set station PRIVATE | ||
+ | Alternative way to select call mode PRIVATE. | ||
+ | Procedure: Dial 7887. If the feature is allowed, a success tone is heard, else a failure tone. The setting is permanent (stored in NVRAM, survives reset). | ||
+ | Configuration: There is a flag in AlphaPro that decide if this station's OPEN/PRIVATE status is controlled by feature codes OR by station hardware. (User/More../Programmable Open/Private). | ||
+ | Application: | ||
+ | • Fixed functionality often required, where the station must ignore the PRIVATE switch. | ||
+ | • EMC problems with PRIVATE switch in wall stations. Now solved by removing the switch, and use keypad for PRIVATE mode. | ||
+ | |||
+ | |||
'''80 FEAT_OPEN_PRIVATE''' | '''80 FEAT_OPEN_PRIVATE''' | ||
{| border="1" | {| border="1" |
Revision as of 22:15, 28 January 2008
Feature: | Follow Me |
Default directory number: | 7886, 7887 |
Feature number: | 80 |
Parameter 1: | 0 = Open 1= Private |
Description: | Feature for activating Follow me (e.g. remote Call Forwarding)
Procedure: On the remote station, dial 72 + own station number to forward calls to the remote station.
|
Alternative way to select call mode OPEN. Procedure: Dial 7886. If the feature is allowed, a success tone is heard, else a failure tone. The setting is permanent (stored in NVRAM, survives reset). Configuration: There is a flag in AlphaPro that decide if this station's OPEN/PRIVATE status is controlled by feature codes OR by station hardware. (User/More../Programmable Open/Private). Application: • Fixed functionality often required, where the station must ignore the PRIVATE switch. • EMC problems with PRIVATE switch in wall stations. Now solved by removing the switch, and use keypad for PRIVATE mode. Version: AMC 06.00 DirNo: 7886 Feature: 80/0 (Db ref. 587) 3.1.7. Feature idle: Set station PRIVATE Alternative way to select call mode PRIVATE. Procedure: Dial 7887. If the feature is allowed, a success tone is heard, else a failure tone. The setting is permanent (stored in NVRAM, survives reset). Configuration: There is a flag in AlphaPro that decide if this station's OPEN/PRIVATE status is controlled by feature codes OR by station hardware. (User/More../Programmable Open/Private). Application: • Fixed functionality often required, where the station must ignore the PRIVATE switch. • EMC problems with PRIVATE switch in wall stations. Now solved by removing the switch, and use keypad for PRIVATE mode.
80 FEAT_OPEN_PRIVATE
Param1 | Description |
---|---|
?? | Toggle functional OPEN/PRIVATE on station |
Alternative to mechanical PRIVATE switch.
Mode 0 = OPEN. Mode 1 = PRIVATE (must be enabled per station). |