Difference between revisions of "CDC CMD"
From Zenitel Wiki
Line 32: | Line 32: | ||
6 BACKUP_IN_PROGRESS <br> | 6 BACKUP_IN_PROGRESS <br> | ||
7 MISSING_DATABASE <br> | 7 MISSING_DATABASE <br> | ||
− | 8 EXTENSION_LOCKED <br> | + | 8 EXTENSION_LOCKED <br> |
− | 9 BARRING_LEVEL <br> | + | 9 BARRING_LEVEL <br> |
10 USERS_MULTIPLE_CALL_INHIBIT <br> | 10 USERS_MULTIPLE_CALL_INHIBIT <br> | ||
11 EXTENSION_INVALID <br> | 11 EXTENSION_INVALID <br> |
Revision as of 13:52, 10 March 2009
Related to ABSD_Billing
CDC_CMD | 0x009F | 159 | AMC 10.40 | |
---|---|---|---|---|
Message used for billing control. <br\>
Call Detail Control message, response to CDC_STATE. command. Used from ABSD towards AMCD | ||||
1 | UINT2 | Connection Reference for this "dialing" sequence (actually ST_IND of A-station). | ||
2 | NET_OBJ_REF | A-station (billed station) . | ||
3 | UINT1 | Command 1 DIAL_PIN, (dial pin code , display *) | ||
4 | UINT1 | ABORT reason codes [1..99] ABSD expects immediate DISCONNECT from AMCD 1 NO_BILLING_LICENSE 8 EXTENSION_LOCKED 10 USERS_MULTIPLE_CALL_INHIBIT ABORT information codes [101..199] 101 OUT_OF_SERVICE, lost contact with Network Disk or other SQLITE specific error status | ||
5 | UINT1 | number of digits to delete from out-buffer | ||
6 | NET_OBJ_REF | For TRUNK_SET: Trunknumber | ||
7 | TEXT16 | Additonal info as text (Abort reason, user name). |