Actions

Difference between revisions of "No data on serial ports"

From Zenitel Wiki

Line 10: Line 10:
 
=== Modification ===
 
=== Modification ===
 
Modification (PCB 8000/3 and earlier): Take away R698 and R695 and connect these to Vcc (3,3V).
 
Modification (PCB 8000/3 and earlier): Take away R698 and R695 and connect these to Vcc (3,3V).
 +
 +
 +
[[Category: Troubleshooting]]
 +
[[Category: AlphaCom Troubleshooting]]

Revision as of 11:22, 12 March 2009

On AMC-IP boards with PCB version 8000/3 and earlier there is a possible problem with the RS-232 serial ports. In the AMC-IP hardware version 8000/4 this problem is resolved.


Location of R695 and R698

Description

The PCB version 8000/3 has a "auto shut-down" feature on the RS232 driver. The RS232 transceiver (MAX3221) will shut down if no valid transitions are detected on receiving and transmitting side. If the connected equipment only is connected, and not sending, the transceiver will shut down when more than 30 seconds pass without data traffic from AMC-IP. The transceiver will turn back on when valid transitions are detected, but this will take some time, and data will be lost. It is strongly recommended to do the hardware modification in order to ensure proper operation. The problem applies to both serial ports. In the latest AMC-IP hardware version, PCB 8000/4, this modification is implemented.

Modification of AMC-IP

Modification

Modification (PCB 8000/3 and earlier): Take away R698 and R695 and connect these to Vcc (3,3V).