Difference between revisions of "IP Flush Master and IP Flush Handset compatibility"
From Zenitel Wiki
Line 1: | Line 1: | ||
[[File:HandsetCRMV.PNG|thumb|250px|Handset module 1008071000 for IP Flush Master]] | [[File:HandsetCRMV.PNG|thumb|250px|Handset module 1008071000 for IP Flush Master]] | ||
− | There are two main hardware revisions of the Handset | + | There are two main hardware revisions of the Handset 1008097100 for IP Flush Master stations. Compatibility with the IP Flush Master station is as follows: |
− | =Handset revision | + | =Handset revision 1008097100.0300 or newer (from May 2013)= |
* Used with IP Flush Master revision 1008031000.0400 or newer: The handset is directly compatible with the IP Flush Master. Connect the handset to the handset connector of the station. | * Used with IP Flush Master revision 1008031000.0400 or newer: The handset is directly compatible with the IP Flush Master. Connect the handset to the handset connector of the station. | ||
* Used with IP Flush Master revision 1008031000.0301 or older: | * Used with IP Flush Master revision 1008031000.0301 or older: | ||
Line 8: | Line 8: | ||
:* Log on to the StationWeb. In '''Advanced Configuration''' -> '''Audio''', enable the flag “Handset in Headset Slot” | :* Log on to the StationWeb. In '''Advanced Configuration''' -> '''Audio''', enable the flag “Handset in Headset Slot” | ||
[[File:IPFlushComp1.PNG|thumb|left|500px|How to enable the flag “Handset in Headset Slot” in '''Advanced Configuration''' -> '''Audio''']] | [[File:IPFlushComp1.PNG|thumb|left|500px|How to enable the flag “Handset in Headset Slot” in '''Advanced Configuration''' -> '''Audio''']] | ||
− | <br style="clear:both;"/> | + | <br style="clear:both;" /> |
:* Connect the Handset to the HEADSET-connector of the station | :* Connect the Handset to the HEADSET-connector of the station | ||
− | =Handset revision | + | =Handset revision 1008097100.0201 or older= |
* Used with IP Flush Master revision 1008031000.0301 or older: The handset is directly compatible with the IP Flush Master. Connect the handset to the handset connector of the station. | * Used with IP Flush Master revision 1008031000.0301 or older: The handset is directly compatible with the IP Flush Master. Connect the handset to the handset connector of the station. | ||
* Used with IP Flush Master revision 1008031000.0400 or newer: | * Used with IP Flush Master revision 1008031000.0400 or newer: | ||
Line 20: | Line 20: | ||
=About noise in the ear-piece of the handset= | =About noise in the ear-piece of the handset= | ||
− | When handset revision | + | When handset revision 1008097100.0201 or older is used with IP Flush Master revision 1008031000.0301 or older, one might experience noise in the ear-piece of the handset. This can be improved by upgrading the handset to revision 1008097100.0300, and use the headset connector of the station. |
Procedure: | Procedure: |
Revision as of 14:39, 19 April 2017
There are two main hardware revisions of the Handset 1008097100 for IP Flush Master stations. Compatibility with the IP Flush Master station is as follows:
Handset revision 1008097100.0300 or newer (from May 2013)
- Used with IP Flush Master revision 1008031000.0400 or newer: The handset is directly compatible with the IP Flush Master. Connect the handset to the handset connector of the station.
- Used with IP Flush Master revision 1008031000.0301 or older:
- Update the software of the IP Flush Master to version 02.3.3.1 or later
- Log on to the StationWeb. In Advanced Configuration -> Audio, enable the flag “Handset in Headset Slot”
- Connect the Handset to the HEADSET-connector of the station
Handset revision 1008097100.0201 or older
- Used with IP Flush Master revision 1008031000.0301 or older: The handset is directly compatible with the IP Flush Master. Connect the handset to the handset connector of the station.
- Used with IP Flush Master revision 1008031000.0400 or newer:
- Upgrade the handset to revision 0300 by dismantling the handset by unscrewing the two screws, flip the circuit board over and solder a strap as shown in the image.
- Connect the handset to the handset connector of the station.
About noise in the ear-piece of the handset
When handset revision 1008097100.0201 or older is used with IP Flush Master revision 1008031000.0301 or older, one might experience noise in the ear-piece of the handset. This can be improved by upgrading the handset to revision 1008097100.0300, and use the headset connector of the station.
Procedure:
- Dismantle the handset by unscrewing the two screws
- Flip the circuit board over and solder a strap as shown in the image
- Update the software of the IP Flush Master to version 02.3.3.1 or later
- Log on to the StationWeb. In Advanced Configuration -> Audio, enable the flag “Handset in Headset Slot”
- Connect the handset to the HEADSET-connector of the station
NOTE: The option to use the headset input also for handset is a workaround available in AlphaCom-mode only.