Actions

Difference between revisions of "TMIS Indication LEDs"

From Zenitel Wiki

(Created page with "=LEDs on Front Plate= '''Status LEDs''' :- '''Talk icon''' lights '''green''' when a call is active and in conversation :- '''Door icon''' lights '''red''' when the door is un...")
 
(LEDs on Front Plate)
Line 1: Line 1:
 
=LEDs on Front Plate=
 
=LEDs on Front Plate=
 
'''Status LEDs'''
 
'''Status LEDs'''
:- '''Talk icon''' lights '''green''' when a call is active and in conversation
+
:- '''Talk icon LED''' lights '''amber''' when a call is active and in conversation
:- '''Door icon''' lights '''red''' when the door is unlocked or relay is active
+
:- '''Door icon LED''' lights '''green''' when the door is unlocked or relay is active
 
[[File:TMIS-1 LED icon1.PNG|thumb|300px|left]]
 
[[File:TMIS-1 LED icon1.PNG|thumb|300px|left]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
  
'''Talk Icon: Flashing at 1 second intervals'''
+
'''Talk Icon LED: Flashing at 1 second intervals'''
 
Station has no connection to the AlphaCom server/exchange.
 
Station has no connection to the AlphaCom server/exchange.
  
Line 20: Line 20:
  
  
'''Talk Icon: Flashing at 5 second intervals'''
+
'''Talk Icon LED: Flashing at 5 second intervals'''
 
Station connected but NOT registered in the AlphaCom server/exchange.  
 
Station connected but NOT registered in the AlphaCom server/exchange.  
 
Reason:
 
Reason:

Revision as of 11:04, 13 October 2016

LEDs on Front Plate

Status LEDs

- Talk icon LED lights amber when a call is active and in conversation
- Door icon LED lights green when the door is unlocked or relay is active
TMIS-1 LED icon1.PNG



Talk Icon LED: Flashing at 1 second intervals Station has no connection to the AlphaCom server/exchange.

Possible reasons:

  • No connection to Ethernet
  • Wrong AlphaCom XE IP address configured
  • Invalid IP address
  • No gateway or wrong gateway to the AlphaCom server/exchange
TMIS-1 LED icon2.PNG



Talk Icon LED: Flashing at 5 second intervals Station connected but NOT registered in the AlphaCom server/exchange. Reason:

  • Station has not been programmed in AlphaPro
TCIS Indications 3.PNG


Status LEDs on PCB

TCIS Board Indications 1.png


Flashing 2 red + 1 green

  • Station has no connection to the AlphaCom server.

Flashing 1 red + 2 green

  • Station connected but NOT registered in the AlphaCom server.

Flashing 3 green

  • Station connected and registered in the AlphaCom server.

Ethernet Activity & Speed LEDs on PCB

TCIS Board Indications 2.png


Green LED

  • Steady light: Ethernet connection OK
  • Flashing: Ethernet data traffic
  • No light: No Ethernet connection

Yellow LED

  • Steady light: 100 Mbit Ethernet connection
  • No light: 10 Mbit Ethernet connection