DAK-48 Unit

The IP DAK-48 unit expands the IP Flush Master station with an additional 48 Direct Access Keys. This unit can also be used with the IP OR Station and the IP Master Station Kit.

Before installation, disconnect power from the IP Flush Master station

The accompanying RJ45-RJ45 cable is used to install the DAK unit on an IP Flush Master station. This cable has an RJ45 plug at both ends. The two ends are interchangeable. Up to two DAK units can be installed per station. Each DAK unit has two RJ45 ports, one located on the left side and one on the right side.

To install the IP DAK-48 Unit:

  • Plug one end of the RJ45-RJ45 cable into the RJ45 port on the right of the station (when the station is viewed from the front).
  • Plug the other end of the RJ45-RJ45 cable into the left (when the unit is viewed from the front) RJ45 port on the DAK unit.

IP Master DAK-48 Unit Installation.PNG
Installing the IP DAK-48 Unit

To add another DAK unit, plug one end of an RJ45-RJ45 cable into the RJ45 port of 
the installed unit and plug the other end into the RJ45 port of the new unit.