Line 27: Line 27:
* Station connected and registered to the AlphaCom XE Audio Server
* Station connected and registered to the AlphaCom XE Audio Server
* Station not powered up (if no other LEDs are active)
* Station not powered up (if no other LEDs are active)
===Status LED===
Bicolor SMD LED on board component side.
[[File:IPSub Indications 1.png|left|thumb|300px|Status LED]]
<br style="clear:both;" />
'''Blinking 2 red + 1 green:''' <br>
* Station has no connection to the AlphaCom XE Audio Server.
'''Blinking 1 red + 2 green:'''<br>
* Station connected but NOT registered in the AlphaCom XE Audio Server.
'''Blinking 3 green:'''<br>
* Station connected and registered in the AlphaCom XE Audio Server.


===LAN LEDs===
===LAN LEDs===

Revision as of 10:47, 26 October 2016

Station LED

IP Substation LED
IP Substation (3gang) LED


Blinking at 1 second intervals:
Station has no connection to the AlphaCom XE Audio Server.

Possible reasons:

  • No connection to Ethernet
  • Wrong AlphaCom IP address configured
  • Invalid IP address
  • No gateway or wrong gateway to the AlphaCom XE Audio Server

Blinking at 5 second intervals:
Station connected but NOT registered in the AlphaCom XE Audio Server.

Possible reasons:

  • Station has not been programmed in AlphaPro
  • Missing IP Station license in AlphaCom XE Audio Server

No blinking:

Possible reasons:

  • Station connected and registered to the AlphaCom XE Audio Server
  • Station not powered up (if no other LEDs are active)

LAN LEDs

Left LED:

Left LED


  • Steady light: Ethernet connection OK
  • Blinking: Ethernet traffic
  • No light: No Ethernet connection

Right LED:

Right LED


  • Light: 100 Mbit Ethernet connection
  • No light: 10 Mbit Ethernet connection