This procedure will load factory defalt settings in the station. The unit can be set to use either '''Static IP''' or '''DHCP'''. | This procedure will load factory defalt settings in the station. The unit can be set to use either '''Static IP''' or '''DHCP'''. | ||
− | # | + | # '''Lift the handset''', and power up the station. |
# Replace the handset '''after exactly 2 flashes''' of the station LED. | # Replace the handset '''after exactly 2 flashes''' of the station LED. | ||
# Let the LED flash for '''exactly 2 more times''' (Static IP) or '''exactly 4 more times''' (DHCP), then lift the handset again. | # Let the LED flash for '''exactly 2 more times''' (Static IP) or '''exactly 4 more times''' (DHCP), then lift the handset again. |
Revision as of 17:07, 20 March 2017
This procedure is applicable for the IP Hotline Station.
Procedure:
This procedure will load factory defalt settings in the station. The unit can be set to use either Static IP or DHCP.
- Lift the handset, and power up the station.
- Replace the handset after exactly 2 flashes of the station LED.
- Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then lift the handset again.
- Keep the handset lifted until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
- Replace the handset and the station will restart with the factory default settings.
Factory default values:
- Station Mode: Pulse
- Station IP address: 169.254.1.100 (Static) or DHCP
- Username: admin
- Password: alphaadmin
It may be desired to reset an IP Hotline Station to its original settings if, for instance, the password for the web server is forgotten.
The defaults can be either be set to Static IP or Activated DHCP (when there are many new IP Substations in an installation).
Restore with Static IP
- While lifting the handset, power up the station.
- When the station LED starts blinking, replace the handset after exactly 2 blinks.
- Let the LED blink for exactly 2 more times, then lift the handset again.
- Keep the handset lifted until the LED blinks fast 2 times indicating a successful reset with static IP.
- Replace the handset and the station will restart with the factory default settings.
Factory default values | |
---|---|
Station Mode | Pulse |
Station IP address | 169.254.1.100 |
AlphaCom IP address | 169.254.1.5 |
Username* | admin |
Password* | alphaadmin |
* Software 01.06 and earlier: ADMIN/alphacom)
Restore with Activated DHCP
The DHCP option is available from software version 01.07.
- While lifting the handset, power up the station.
- When the station LED starts blinking, replace the handset after exactly 2 blinks.
- Let the LED blink for exactly 4 more times, then lift the handset again.
- Keep the handset lifted until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
- Replace the handset and the station will restart with the factory default settings.
Factory default values | |
---|---|
Station Mode | Pulse |
Station IP address | determined by DHCP server |
AlphaCom IP address | 169.254.1.5 |
Username* | admin |
Password* | alphaadmin |