Difference between revisions of "VS-SDK for AlphaCom"
From Zenitel Wiki
m (→Licensing) |
m |
||
Line 31: | Line 31: | ||
The DLL contains one name space: | The DLL contains one name space: | ||
*State | *State | ||
+ | ==Communication with the AlphaCom XE exchange== | ||
+ | Software based on the SDK have 2 possibilities to communicate with AlphaCom: | ||
+ | *Direct connection to either TCP port 61112 or 61113 | ||
+ | *Connection via a 'Service Provider' | ||
+ | ===Direct connection=== | ||
+ | AlphaCom has 2 communication ports available for API/OPC based software, ports 61112 and 61113. These 2 ports are independent. In an AlphaNet, it is possible to use up to 10 ports, divided over at least 5 exchanges (this AlphaNet capability is available as from AMC-IP software version a.d.c.d). | ||
+ | |||
+ | ===Service provider=== | ||
+ | Sometimes there is a requirement for more connection points to an AlphaCom. As from SDK version 2.1.3.1 an 'Service provider' will be included. This serveice provider will itself connect to either port 61112 or 61113 but then make multiple ports available for other software to connect. In effect the service provider acts as a port expander. | ||
+ | |||
+ | ===TCP communication ports=== | ||
+ | To be able to communicate with either of port 61112 or 61113, the port must be enabled in the exchange using AlphaWeb, the web server which is integrated in the AlphaCom xE. | ||
+ | Log in to AlphaWeb and select ‘System Configuration/Filters’ and enable the required port number for the physical Ethernet port the API will connect to. | ||
==Sample software== | ==Sample software== |
Revision as of 11:45, 16 October 2017
This article is under construction. The software described here is not available yet.
Contents
Introduction
Licensing
The possibility to retrieve intercom station state information from the exchange is a licensed feature, and requires the presence of an ‘API/OPC interface’ license in the AlphaCom XE exchange for at least as many stations as that of the status to be retrieved.
Note that every AlphaCom in an AlphaNet requires such a license.
- 1009649901 - STENTOFON API License Supporting 40 Stations
- 1009649902 - STENTOFON API License Supporting 80 Stations
- 1009649903 - STENTOFON API License Supporting 160 Stations
- 1009649904 - STENTOFON API License Supporting 240 Stations
- 1009649905 - STENTOFON API License Supporting 320 Stations
- 1009649906 - STENTOFON API License Supporting 400 Stations
- 1009649907 - STENTOFON API License Supporting 552 Stations
DLL description
Stentofon.AlphaCom.AlphaNet.dll
The Stentofon.AlphaCom.AlphaNet.dll implements the AlphaCom Data Protocol and handles the communication with the AlphaCom XE exchanges. It raises events and exposes methods to be able to receive data from, and send commands to the exchange. The .dll supports auto-discovery of the complete AlphaCom XE network configuration. This makes the system very easy to configure and set up. In addition, the .dll will track and report all state changes in the AlphaCom XE network which the 3rd program subscribes to. The .dll supports the STENTOFON AlphaNet. This means that all AlphaCom XE exchanges and stations in a network can be addressed by having an IP connection to just one of the AlphaCom XE exchanges. The .dll requires Microsoft .NET 4.6.2 The DLL contains three name spaces:
- Messages
- Client
- Config
Stentofon.AlphaCom.Data.dll
The Stentofon.AlphaCom.Data.dll is not strictly required, but it provides a standardized way of storing and retrieving AlphaCom XE network, exchange and station information and states. Storage can be in an MSSQL database or in memory ’AlphaComStateStorages.MSSQL’ or ‘AlphaComStateStorages.IN_MEMORY’. The .dll requires Microsoft .NET 4.6.2 The DLL contains one name space:
- State
Communication with the AlphaCom XE exchange
Software based on the SDK have 2 possibilities to communicate with AlphaCom:
- Direct connection to either TCP port 61112 or 61113
- Connection via a 'Service Provider'
Direct connection
AlphaCom has 2 communication ports available for API/OPC based software, ports 61112 and 61113. These 2 ports are independent. In an AlphaNet, it is possible to use up to 10 ports, divided over at least 5 exchanges (this AlphaNet capability is available as from AMC-IP software version a.d.c.d).
Service provider
Sometimes there is a requirement for more connection points to an AlphaCom. As from SDK version 2.1.3.1 an 'Service provider' will be included. This serveice provider will itself connect to either port 61112 or 61113 but then make multiple ports available for other software to connect. In effect the service provider acts as a port expander.
TCP communication ports
To be able to communicate with either of port 61112 or 61113, the port must be enabled in the exchange using AlphaWeb, the web server which is integrated in the AlphaCom xE. Log in to AlphaWeb and select ‘System Configuration/Filters’ and enable the required port number for the physical Ethernet port the API will connect to.