Difference between revisions of "TCAS Connections"
From Zenitel Wiki
(→Second Call Key) |
|||
Line 21: | Line 21: | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | == | + | == Second Call Key == |
The station is prepared for a future second call key (DAK2). | The station is prepared for a future second call key (DAK2). | ||
Revision as of 12:14, 16 August 2018
This article describers all Turbine Compact Analog Standard Station connections.
The Turbine analog station has an RJ-45 port and 6 external connectors.
Power | Draws power from AlphaCom signal line |
RJ-45 port | AlphaCom connection |
A, B, C, D wires | AlphaCom connection when RJ-45 port is not used |
Note! Use cables crimped with ferrules for terminal block connectors
To set up the analog station as an intercom:
- 1. Connect the RJ-45 port on the station to the AlphaCom exchange
- 2. Register the station in the AlphaCom exchange
For details on connection at the AlphaCom server side, see ASLT - AlphaCom Subscriber Line Board
Second Call Key
The station is prepared for a future second call key (DAK2).
This second call key can be found on the print if wanted and utilized with an external call button.
- A second external call key must be connected between the A-wire and the lower leg on D6 (highlighted in the image above).