Difference between revisions of "TFIE Indication LEDs"
From Zenitel Wiki
Line 1: | Line 1: | ||
− | =LEDs on Front Plate= | + | ==LEDs on Front Plate== |
'''Power LED - Green:''' | '''Power LED - Green:''' | ||
* Steady light: Power is OK | * Steady light: Power is OK | ||
Line 11: | Line 11: | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | =Status LEDs on PCB= | + | ==Status LEDs on PCB== |
[[File:TFIE Board Indications 1.png|thumb|left|500px]] | [[File:TFIE Board Indications 1.png|thumb|left|500px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
Line 23: | Line 23: | ||
* Station connected and registered in the AlphaCom server/exchange. | * Station connected and registered in the AlphaCom server/exchange. | ||
− | =Ethernet Activity & Speed LEDs on PCB= | + | ==Ethernet Activity & Speed LEDs on PCB== |
[[File:TFIE Board Indications 2.png|thumb|left|500px]] | [[File:TFIE Board Indications 2.png|thumb|left|500px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> |
Revision as of 08:32, 12 April 2019
LEDs on Front Plate
Power LED - Green:
- Steady light: Power is OK
Fault LED - Yellow:
- Steady light: Not used
- Flashing: Not registered/no connection to server
Call LED - Red:
- Steady light: In a conversation/call
Status LEDs on PCB
Flashing 2 red + 1 green:
- Station has no connection to the AlphaCom server/exchange.
Flashing 1 red + 2 green:
- Station connected but NOT registered in the AlphaCom server/exchange.
Flashing 3 green
- Station connected and registered in the AlphaCom server/exchange.
Ethernet Activity & Speed LEDs on PCB
Green LED:
- Steady light: Ethernet connection OK
- Flashing: Ethernet data traffic
- No light: No Ethernet connection
Yellow LED:
- Steady light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection