Difference between revisions of "IP-LCM Configuration (AlphaCom mode)"
From Zenitel Wiki
Line 2: | Line 2: | ||
This article describes how to configure the inputs and ooutputs of the [[IP-LCM|IP-LCM Module]] when used with an AlphaCom server. | This article describes how to configure the inputs and ooutputs of the [[IP-LCM|IP-LCM Module]] when used with an AlphaCom server. | ||
− | The IP-LCM requires an [[Licenses#IP_station_license|IP Station License]] in order to register to the AlphaCom server. | + | == Basic configuration == |
+ | * The IP-LCM requires an [[Licenses#IP_station_license|IP Station License]] in order to register to the AlphaCom server. | ||
+ | * The IP-LCM is configured in the same way as other Turbine devices, see [[Turbine Configuration - AlphaCom mode|Turbine configuration]] | ||
== Inputs == | == Inputs == |
Revision as of 13:33, 17 April 2019
This article describes how to configure the inputs and ooutputs of the IP-LCM Module when used with an AlphaCom server.
Basic configuration
- The IP-LCM requires an IP Station License in order to register to the AlphaCom server.
- The IP-LCM is configured in the same way as other Turbine devices, see Turbine configuration
Inputs
The IP-LCM module has in total 14 inputs:
- 6 inputs on the The TKIS-2 module itself
- 8 inputs on the IP-LCM board
- The six inputs on the TKIS-2 module are triggered by connecting the Input to GND.
- Depending on switch settings the eight inputs on the IP-LCM board are triggerd either by a close contact (default), or by a DC voltage signal. See IP-LCM Connections for details.
- The IP-LCM is configured in the same way as other Turbine devices, see Turbine configuration
- The 8 inputs of the IP-LCM module are triggering event 30, DAK/Input 18-25. See RCI configuration
- The 8 relays must be mapped to RCO pins 17-24, see RCO - Remote Control Output