WinGuard is the PSIM software from Advancis. Integration between WinGuard and ICX or AlphaCom system is via the ACDP protocol ([[AlphaNet Data Protocol]]), using the link type Simple Link Layer. The following paragraphs give a short setup guide of the system, for more details please contact Advancis directly. | WinGuard is the PSIM software from Advancis. Integration between WinGuard and ICX or AlphaCom system is via the ACDP protocol ([[AlphaNet Data Protocol]]), using the link type Simple Link Layer. The following paragraphs give a short setup guide of the system, for more details please contact Advancis directly. | ||
+ | |||
+ | ==Licenses == | ||
+ | In the ICX System the following license is required in order to enable the ACDP protocol: 1002602400 - ILI-IF Interface enabling | ||
==ICX and AlphaCom Setup== | ==ICX and AlphaCom Setup== |
Revision as of 15:40, 18 November 2019
General
WinGuard is the PSIM software from Advancis. Integration between WinGuard and ICX or AlphaCom system is via the ACDP protocol (AlphaNet Data Protocol), using the link type Simple Link Layer. The following paragraphs give a short setup guide of the system, for more details please contact Advancis directly.
Licenses
In the ICX System the following license is required in order to enable the ACDP protocol: 1002602400 - ILI-IF Interface enabling
ICX and AlphaCom Setup
AlphaPro
Configure the ACDP port to be used towards WinGuard.
From the AlphaPro main menu, select Exchange & System > Serial Ports, and select one of the available ACDP links and program as follows:
- Port Type: TCP/IP server
- Link Type: Stentofon Simple Link Layer
- Broadcast: Enabled
- Port: Enter a TCP/IP port nr on which WinGuard and ICX/AlphaCom will communicate, default for WinGuard is 4001
- Keep Alive: Enabled
Web settings