[[File:TFIE Board Indications 1.png|thumb|left|500px]] | [[File:TFIE Board Indications 1.png|thumb|left|500px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | *'''Flashing 2 red + 1 green:''' Station has no connection to the AlphaCom server | + | *'''Flashing 2 red + 1 green:''' Station has no connection to the ICX-AlphaCom server. |
− | *'''Flashing 1 red + 2 green:''' Station connected but NOT registered in the AlphaCom server | + | *'''Flashing 1 red + 2 green:''' Station connected but NOT registered in the ICX-AlphaCom server. |
− | *'''Flashing 3 green''' Station connected and registered in the AlphaCom server | + | *'''Flashing 3 green''' Station connected and registered in the ICX-AlphaCom server. |
<br> | <br> |
Revision as of 08:25, 20 November 2020
Contents
LEDs in Front Panel
- Power (Green): Steady light when power is OK
- Fault (Yellow): Flashing when the station is not registered/no connection to server
- Call (Red): Steady light during a conversation/call
LEDs in Function Keys/DAK keys
When a TFIE station is used in AlphaCom mode, the LEDs in the DAK keys can be controlled from the Event Handler by using the IND command.
Status LEDs on PCB
- Flashing 2 red + 1 green: Station has no connection to the ICX-AlphaCom server.
- Flashing 1 red + 2 green: Station connected but NOT registered in the ICX-AlphaCom server.
- Flashing 3 green Station connected and registered in the ICX-AlphaCom server.
Ethernet Activity & Speed LEDs on PCB
Green LED:
- Steady light: Ethernet connection OK
- Flashing: Ethernet data traffic
- No light: No Ethernet connection
Yellow LED:
- Steady light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection