Actions

Difference between revisions of "TFIE Indication LEDs"

From Zenitel Wiki

(Status LEDs on PCB)
Line 16: Line 16:
 
[[File:TFIE Board Indications 1.png|thumb|left|500px]]
 
[[File:TFIE Board Indications 1.png|thumb|left|500px]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
*'''Flashing 2 red + 1 green:''' Station has no connection to the AlphaCom server/exchange.
+
*'''Flashing 2 red + 1 green:''' Station has no connection to the ICX-AlphaCom server.
*'''Flashing 1 red + 2 green:''' Station connected but NOT registered in the AlphaCom server/exchange.
+
*'''Flashing 1 red + 2 green:''' Station connected but NOT registered in the ICX-AlphaCom server.
*'''Flashing 3 green''' Station connected and registered in the AlphaCom server/exchange.
+
*'''Flashing 3 green''' Station connected and registered in the ICX-AlphaCom server.
  
 
<br>
 
<br>

Revision as of 08:25, 20 November 2020

LEDs in Front Panel

TFIE Indications 1.PNG


  • Power (Green): Steady light when power is OK
  • Fault (Yellow): Flashing when the station is not registered/no connection to server
  • Call (Red): Steady light during a conversation/call


LEDs in Function Keys/DAK keys

When a TFIE station is used in AlphaCom mode, the LEDs in the DAK keys can be controlled from the Event Handler by using the IND command.


Status LEDs on PCB

TFIE Board Indications 1.png


  • Flashing 2 red + 1 green: Station has no connection to the ICX-AlphaCom server.
  • Flashing 1 red + 2 green: Station connected but NOT registered in the ICX-AlphaCom server.
  • Flashing 3 green Station connected and registered in the ICX-AlphaCom server.


Ethernet Activity & Speed LEDs on PCB

TFIE Board Indications 2.png


Green LED:

  • Steady light: Ethernet connection OK
  • Flashing: Ethernet data traffic
  • No light: No Ethernet connection

Yellow LED:

  • Steady light: 100 Mbit Ethernet connection
  • No light: 10 Mbit Ethernet connection