Actions

Difference between revisions of "School Intercom Station LED Indicators"

From Zenitel Wiki

(Station LED)
Line 17: Line 17:
  
 
Possible reasons:  
 
Possible reasons:  
* Station connected and registered to the ICX-AlphaCom Server
+
* Station connected and registered to the server/controller
 
* Station not powered up (if no other LEDs are active)
 
* Station not powered up (if no other LEDs are active)
  

Revision as of 11:43, 20 November 2020

Station LED

Station LED


Blinking at 1 second intervals:
Station cannot register to the server/controller

Possible reasons:

  • Invalid network settings (IP address and network mask) in the device
  • Wrong or missing account settings (Server IP, directory number, password..)
  • Failing to register due to missing license in the server
  • The server is offline
  • Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)

If the server is on a different subnet, check that

  • A valid Default gateway is defined

No blinking:

Possible reasons:

  • Station connected and registered to the server/controller
  • Station not powered up (if no other LEDs are active)

Blinking at 5 second intervals:

Note icon This LED behaviour only applies in ICX-AlphaCom mode


Station connected but NOT registered in the ICX-AlphaCom

Possible reasons:

  • Station has not been programmed in AlphaPro
  • Missing IP Station license in ICX-AlphaCom