Actions

Difference between revisions of "TCIS Restore Factory Defaults"

From Zenitel Wiki

(Factory default values)
Line 2: Line 2:
  
  
==Reset to Factory Default Settings with Activated DHCP==
+
==Reset to Factory Default Settings with DHCP==
 
<div style="text-align:left;"> <youtube width="300" height="180">6dZHLvSKt_I</youtube>  </div>
 
<div style="text-align:left;"> <youtube width="300" height="180">6dZHLvSKt_I</youtube>  </div>
 
<br><br>
 
<br><br>
Line 8: Line 8:
 
'''To reset:'''
 
'''To reset:'''
  
:1.  While '''pressing any button''', power up the station by connecting it to a PoE switch.
+
#While '''pressing any button''', power up the station by connecting it to a PoE switch.
:2.  Hold the button until the station audio starts counting, and release the button on '''count 1'''.
+
#Hold the button until the station audio starts counting, and release the button on '''count 1'''.
:3.  Press and hold the button on '''count 5''' and release on '''count 0'''.
+
#Press and hold the button on '''count 5''' and release on '''count 0'''.
 
::- if there is no 0 count, the procedure has failed and you have to start again
 
::- if there is no 0 count, the procedure has failed and you have to start again
:4.  Press the '''call button''', and the station will speak its IP address
+
#Press the '''call button''', and the station will speak its IP address
  
 
[[File:TCIS Factory Reset 1.PNG|thumb|150px|left|Factory Default with IP address from DHCP server]]
 
[[File:TCIS Factory Reset 1.PNG|thumb|150px|left|Factory Default with IP address from DHCP server]]

Revision as of 09:51, 19 November 2021

APS.png

A Turbine IP Station may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP.


Reset to Factory Default Settings with DHCP



To reset:

  1. While pressing any button, power up the station by connecting it to a PoE switch.
  2. Hold the button until the station audio starts counting, and release the button on count 1.
  3. Press and hold the button on count 5 and release on count 0.
- if there is no 0 count, the procedure has failed and you have to start again
  1. Press the call button, and the station will speak its IP address
Factory Default with IP address from DHCP server


Factory default values

  • Station IP address: Determined by DHCP server. If no DHCP server is available, it gets a random 169.254.x.x address.
  • Username: admin
  • Password: alphaadmin
  • Mode of operation: Edge

Reset to Factory Default Settings with Static IP


To reset:

1. While pressing any button, power up the station by connecting to a PoE switch.
2. Hold the button until the station audio starts counting, and release the button on count 1.
3. Press and hold the button on count 3 and release on count 0.
- if there is no 0 count, the procedure has failed and you have to start again
4. Press the call button, and the station will speak its IP address.
Factory Default with Static IP Address


Factory default values

  • Station IP address: 169.254.1.100
  • Username: admin
  • Password: alphaadmin
  • Mode of operation: Edge