The Open Door script as described in the manual, and as part of standard scripts in Vingtor-Stentofon Operator itself, does not work for both incoming and outgoing calls. This will be rectified in a following release. The correct script is:
string dirop = Av.Params.Get("DIROP", ""); string dira = Av.Params.Get("DIRA", ""); int nnop = Av.Params.Get("NNOP", 0); int nna = Av.Params.Get("NNA", 0); if ((dira==dirop) && (nna==nnop)) { Av.STE ("@U%NNB $ER U2 U0 U1 U1 L%DIRB U3 L(%NNOP)%DIROP"); Av.Delay (3500); Av.STE ("@U%NNB $ER U2 U0 U0 U1 L%DIRB U3 L(%NNOP)%DIROP"); } else { Av.STE ("@U%NNA $ER U2 U0 U1 U1 L%DIRA U3 L(%NNOP)%DIROP"); Av.Delay (3500); Av.STE ("@U%NNA $ER U2 U0 U0 U1 L%DIRA U3 L(%NNOP)%DIROP"); }