Actions

Difference between revisions of "Open door script does not work"

From Zenitel Wiki

Line 21: Line 21:
  
  
[[Category:Vingtor-Stentofon Operator Troubleshooting]]
+
[[Category:VS-Operator Troubleshooting]]

Revision as of 09:34, 7 February 2023

AI.png

The Open Door script as described in the manual, and as part of standard scripts in Vingtor-Stentofon Operator itself, does not work for both incoming and outgoing calls. This will be rectified in a following release. The correct script is:

string dirop = Av.Params.Get("DIROP", ""); 
string dira = Av.Params.Get("DIRA", ""); 
int nnop = Av.Params.Get("NNOP", 0);
int nna = Av.Params.Get("NNA", 0);


if ((dira==dirop) && (nna==nnop))
{
	Av.STE ("@U%NNB $ER U2 U0 U1 U1 L%DIRB U3 L(%NNOP)%DIROP"); 
	Av.Delay (3500);
	Av.STE ("@U%NNB $ER U2 U0 U0 U1 L%DIRB U3 L(%NNOP)%DIROP");
}
else
{
	Av.STE ("@U%NNA $ER U2 U0 U1 U1 L%DIRA U3 L(%NNOP)%DIROP");
	Av.Delay (3500);
	Av.STE ("@U%NNA $ER U2 U0 U0 U1 L%DIRA U3 L(%NNOP)%DIROP");
}