Actions

IP Hotline Connections: Difference between revisions

From Zenitel Wiki

Line 9: Line 9:
These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.  
These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.  


==== P3 - 10-pin plug-on terminal for I/O's and Audio Line Out ====
[[File:TCIS Connections 6.PNG|thumb|300px|left]]
:Pin 1  5.3V (max. 200mA current)
:Pin 2  GND
:Pin 3  Input for Hookswitch for handset cradle (and for restoring Factory Default Setting)
:Pin 4  Button Input or LED Driver
:Pin 5  Button Input or LED Driver
:Pin 6  Button Input or LED Driver
:Pin 7  Button Input or LED Driver
:Pin 8  Button Input or LED Driver
:Pin 9  600 ohm balanced line out +
:Pin 10  600 ohm balanced line out -
<br style="clear:both;" />
* Connectable conductors:  0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².
==== P4 - Loudspeaker & Electret microphone ====
[[File:TCIS Connections 7.PNG|thumb|500px|left]]
<br style="clear:both;" />
:Pin 1: Speaker output +
:Pin 2: Speaker output -
:Pin 3:  Electret Microphone +
:Pin 4:  Electret Microphone -
* Connectable conductors:  0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².
* Recommended loudspeaker impedance: 8 ohms
{{Note | To enable the electret microphone input when using a [[TKIS-2]], the "'''Product Model And Accessory'''" must be set to "'''Kit'''" under [[Main Settings (IP Stations)|Station Main > Main Settings]] in the web interface of the device.}}


For more details see [[Turbine Compact Board Connectors]].
For more details see [[Turbine Compact Board Connectors]].

Revision as of 12:22, 23 June 2023

The IP Hotline comes with either the INCA IP Flush Master board, or the TKIS-2 kit inside.

Turbine Based

Introduction

1008070010 Hotline IP-TKIS.png


Input/Output Connections

There are 6 I/O connection options for the IP Hotline Station. These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.


For more details see Turbine Compact Board Connectors.