(→Control the LED) |
|||
Line 29: | Line 29: | ||
Use the event handler and define situations where the station LED shall be lit: | Use the event handler and define situations where the station LED shall be lit: | ||
* Microphone active: | * Microphone active: | ||
+ | |||
+ | Action is: $SET_IPRCO L%1.dir U2 %chg(1,0) | ||
+ | |||
[[File:TKIE_MicOpen.png|thumb|left|700px]] | [[File:TKIE_MicOpen.png|thumb|left|700px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
* Call Request and Ringing Group call with blinking LED: | * Call Request and Ringing Group call with blinking LED: | ||
+ | |||
+ | Action is: IND %1.phy 12 1 3 %chg(ON,OFF) | ||
+ | |||
[[File:TKIE_CRmode.png|thumb|left|700px]] | [[File:TKIE_CRmode.png|thumb|left|700px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> |
Latest revision as of 11:51, 5 October 2023
The call button and station LED on the TCIA-2 must be configured.
NOTE: TCIA-2 is equipped with one LED in the call button, and this is the green Talk-LED.
Contents
Alphacom - ICX Mode
Call Button
The call button is connected to input 1, and is by default set as input. Input 1 is programmed in AlphaPro as DAK 11 in DAK window, or as sybtype 11 in event 30. Example shows DAK 11 doing Call Request to station 101:
Example shows input 1 calling station 101 using event 30:
LED Settings
Log into the station webserver and navigate to the I/O settings. The station LED is from factory wired to output 2.
Choose I/O and set it as Output.
Control the LED
Use the event handler and define situations where the station LED shall be lit:
- Microphone active:
Action is: $SET_IPRCO L%1.dir U2 %chg(1,0)
- Call Request and Ringing Group call with blinking LED:
Action is: IND %1.phy 12 1 3 %chg(ON,OFF)
IC-Edge Mode
Call button
The call button is connected to input 1, and is by default set as input. The input is programmed in Edge Controller -> System Configuration -> Direct Access Key (DAK) and Buttons and Inputs. The example below shows how to set up a call to directory number 101. The conversation will be ended if input or call button is pressed during conversation.
LED Settings
Advanced configuration mode must be enabled to make the following changes.
Log into the station webserver and navigate to the I/O settings. The station LED is from factory wired to output 2.
Choose I/O and set it as Output.
Control the LED
In Edge controller, go into System Configuration -> Special Setting and select Relay setting.
Choose to configure output 2 in the listbox. The recommended settings are shown below:
SIP Mode
Call Button
The call button is connected to input 1, and is by default set as input. The input is programmed in SIP Configuration -> Direct Access Key (DAK). The example below shows how to set up a call to directory number 101. The conversation will be ended if input or call button is pressed during conversation.
LED Settings
Advanced configuration mode must be enabled to make the following changes.
Log into the station webserver and navigate to the I/O settings. The station LED is from factory wired to output 2.
Choose I/O and set it as Output.
Control the LED
In the station web server, go into SIP Configuration -> Relays/Outputs.
Choose to configure output 2 in the listbox. The recommended settings are shown below: