Actions

Zenitel IP Speaker connectors: Difference between revisions

From Zenitel Wiki

No edit summary
No edit summary
 
Line 11: Line 11:
| align="center" style="background:#ffd400;" |'''''Comment'''''
| align="center" style="background:#ffd400;" |'''''Comment'''''
|-
|-
| || GPIO || General Purpose In Out
| 1 || GPIO || General Purpose In Out
|-
|-
| || 5V+ || 5 volt output
| 2 || 5V+ || 5 volt output
|-
|-
| || Ext speaker (8ohm) || Connection for external 8 ohm loudspeaker
| 3 || Ext speaker (8ohm) || Connection for external 8 ohm loudspeaker
|-
|-
| || Ext speaker (8ohm) || Connection for external 8 ohm loudspeaker
| 4 || Ext speaker (8ohm) || Connection for external 8 ohm loudspeaker
|-
|-
| || Int speaker (8ohm) || Connection for internal 8 ohm loudspeaker
| 5 || Int speaker (8ohm) || Connection for internal 8 ohm loudspeaker
|-
|-
| || Int speaker (8ohm) || Connection for internal 8 ohm loudspeaker
| 6 || Int speaker (8ohm) || Connection for internal 8 ohm loudspeaker
|-
|-
| 7 || Relay CO || Relay output, Common   
| 7 || Relay CO || Relay output, Common   
Line 35: Line 35:


{{Note|
{{Note|
¹) Connectable conductors:  0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².
Connectable conductors:  0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².
}}
}}



Latest revision as of 14:24, 13 January 2025

AEIS.png



ZIPSConnections.png


Pin Description Comment
1 GPIO General Purpose In Out
2 5V+ 5 volt output
3 Ext speaker (8ohm) Connection for external 8 ohm loudspeaker
4 Ext speaker (8ohm) Connection for external 8 ohm loudspeaker
5 Int speaker (8ohm) Connection for internal 8 ohm loudspeaker
6 Int speaker (8ohm) Connection for internal 8 ohm loudspeaker
7 Relay CO Relay output, Common
8 Relay NO Relay output, Normal Open
9 Line in/Mic Audio input (positive)
10 Line in/Mic Audio input (negative)
11 GND Ground connector
Note icon

Connectable conductors: 0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².


Note icon
  • Relay switching capacity: Max. 9 watt (Max voltage: 60VAC/60VDC. Max current: 160mA)
  • The 5V output can deliver TBA mA current maximum