PROGRAM 0x0001 1 AMC 05.00
$PROG L101 L801 U1<br\>$PROG L101 LV
Set audio program for single station or a predefined group of stations.
1 NET_OBJ_REF<br\>{ECL_STATION, <BR\> ECL_ST_GROUP} A - user or station.
2 NET_OBJ_REF <br\>{ECL_PROGRAM} Audio program<br\>

- Null value or directory number for “program off” disconnects any active program(s).

3 UINT1 Priority<br\>

1 = Low (default)<br\> 2 = Medium<br\> 3 = High<br\> 4 = Alarm

Response: PROGRAM_ACK, PROGRAM_NAK