Actions

Difference between revisions of "IP School Intercom Station Restore Factory Defaults"

From Zenitel Wiki

Line 16: Line 16:
 
*Password: '''alphaadmin'''
 
*Password: '''alphaadmin'''
  
 
* Software 01.06 and earlier: Username/password is '''ADMIN/alphacom'''
 
  
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]

Revision as of 13:18, 20 March 2017

APS.png

This procedure is applicable for the IP School Intercom Station.

SchoolIndications1.png

Procedure:
This procedure will load factory defalt settings in the station. The unit can be set to use either Static IP or DHCP.

  1. While pressing the emergency button, power up the station and keep the button pressed.
  2. Release the button after exactly 2 flashes of the LED.
  3. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  4. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  5. Release the button and the station will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 (Static) or DHCP
  • Username: admin
  • Password: alphaadmin