Difference between revisions of "Wudd"
From Zenitel Wiki
(→Syntax) |
|||
Line 1: | Line 1: | ||
+ | {{A}} | ||
The '''WUDD''' command is used in the [[Event Handler]] to write a value to [[UDD]] (User Defined Data variable). The value is changed immediately, before the next statement is executed. The WUDD command can only be used to change values in local exchange. In order to write to an UDD in another exchange via AlphaNet, the data command [[WRITE_USER_DEF_DATA|$WUDD]] must be used. <br> | The '''WUDD''' command is used in the [[Event Handler]] to write a value to [[UDD]] (User Defined Data variable). The value is changed immediately, before the next statement is executed. The WUDD command can only be used to change values in local exchange. In order to write to an UDD in another exchange via AlphaNet, the data command [[WRITE_USER_DEF_DATA|$WUDD]] must be used. <br> | ||
From AMC 11.02 alphanumeric storing from event handler is possible (not via $WUDD). Alphanumeric storing is cleared after reset. | From AMC 11.02 alphanumeric storing from event handler is possible (not via $WUDD). Alphanumeric storing is cleared after reset. |
Revision as of 09:21, 11 January 2017
The WUDD command is used in the Event Handler to write a value to UDD (User Defined Data variable). The value is changed immediately, before the next statement is executed. The WUDD command can only be used to change values in local exchange. In order to write to an UDD in another exchange via AlphaNet, the data command $WUDD must be used.
From AMC 11.02 alphanumeric storing from event handler is possible (not via $WUDD). Alphanumeric storing is cleared after reset.
Syntax
WUDD index value WUDD "label" "string" WUDD "label" value
Write value to UDD at the location index, or write value or string to a labeled variable.
- index: 0 – 6000 ( 0 - 600 before AMC 9.01)
- label: 1 - 16 characters label (alpha numeric), must start with alphabetic characters (a-z, A-Z). No space allowed. 30 labels available, cleared on reset.
- value: 32 bit value (16 bit value before AMC 9.03)
- string: 1-128 characters string
Examples
WUDD 8 4321 - Write value 4321 to variable 8 WUDD %1.phy %2.dir - Write the directory number of the 'Related To' station to the location identified by the physical number of the event 'Owner'
WUDD "LastAlarm" "Alarm from %1.nam" LOG "%UDD(LastAlarm)" WUDD "myPhyNumber" %1.phy LOG "My phy = %UDD(myPhyNumber)"
Received in 28-External Data Input:
WUDD "RadioRef" "%scutf(%edi, +,2)" WUDD "RadioAddr" "%scutf(%edi, +,3)"
Used in event trigger:
EDO "%UDD(RadioAddr) %UDD(RadioRef) 32144\x0D\x0A"
See also
Applications were UDD are used:
Related articles: