Difference between revisions of "Program station volume feature"
From Zenitel Wiki
Line 13: | Line 13: | ||
|} | |} | ||
<br> | <br> | ||
− | The [[ASLT]] output level can also be set from the Users & Stations menu in [[AlphaPro]]. | + | The [[ASLT]] output level can also be set from the Users & Stations menu in [[AlphaPro]]. As from AMC ver. 11.2.3.x the relation between the 783 volume setting and AlphaPro setting is as follows: |
+ | |||
+ | $VOL / | ||
+ | AlphaPro 783+n IP-station DIP NVRAM | ||
+ | -------- ----- ---------- --- ----- | ||
+ | -14 0 1 0 242 | ||
+ | -12 244 | ||
+ | -10 246 | ||
+ | -8 1 2 4 248 | ||
+ | -6 250 | ||
+ | -4 2 3 9 252 | ||
+ | -2 254 | ||
+ | 0 3,4 4 13 0 | ||
+ | 2 2 | ||
+ | 4 5,6 5 18 4 | ||
+ | 6 6 | ||
+ | 8 7 6 22 8 | ||
+ | 10 10 | ||
+ | 12 8 7 27 12 | ||
+ | 14 14 | ||
+ | 16 9 8 31 16 | ||
+ | |||
+ | |||
+ | Versions prior to AMC 11.2.3.x: | ||
AlphaPro 783+n IP-station | AlphaPro 783+n IP-station |
Revision as of 14:40, 25 May 2011
Feature: | Set station volume |
Default directory number: | 783 |
Feature number: | 38 |
Parameter 1: | 0 (N/A) |
Description: | Set output level (0-9) on ASLT line board. Primarily to compensate for long wires. Dial: 783 + digit 0-9. Default level is 3. |
The ASLT output level can also be set from the Users & Stations menu in AlphaPro. As from AMC ver. 11.2.3.x the relation between the 783 volume setting and AlphaPro setting is as follows:
$VOL / AlphaPro 783+n IP-station DIP NVRAM -------- ----- ---------- --- ----- -14 0 1 0 242 -12 244 -10 246 -8 1 2 4 248 -6 250 -4 2 3 9 252 -2 254 0 3,4 4 13 0 2 2 4 5,6 5 18 4 6 6 8 7 6 22 8 10 10 12 8 7 27 12 14 14 16 9 8 31 16
Versions prior to AMC 11.2.3.x:
AlphaPro 783+n IP-station -------- ----- ---------- -14 0 -12 1 -10 -8 1 2 -6 -4 2 3 -2 0 3 4 2 4 4 5 5 6 6 8 7 6 10 12 8 7 14 16 9 8
Related AlphaCom Data Protocol message: VOL