Actions

Difference between revisions of "Program station volume feature"

From Zenitel Wiki

Line 19: Line 19:
 
  --------  -----  ----------  ---  -----
 
  --------  -----  ----------  ---  -----
 
   -14        0      1        0    242
 
   -14        0      1        0    242
   -12                             244     
+
   -12                               244     
   -10                             246
+
   -10                               246
 
   -8        1      2        4    248
 
   -8        1      2        4    248
   -6                             250
+
   -6                               250
 
   -4        2      3        9    252
 
   -4        2      3        9    252
   -2                             254
+
   -2                               254
 
     0        3      4        13      0
 
     0        3      4        13      0
 
     2        4                        2
 
     2        4                        2
Line 30: Line 30:
 
     6        6                        6
 
     6        6                        6
 
     8        7      6        22      8
 
     8        7      6        22      8
   10                             10
+
   10                               10
 
   12        8      7        27    12
 
   12        8      7        27    12
   14                             14  
+
   14                               14  
 
   16        9      8        31    16
 
   16        9      8        31    16
  

Revision as of 14:58, 25 May 2011

Feature: Set station volume
Default directory number: 783
Feature number: 38
Parameter 1: 0 (N/A)
Description: Set output level (0-9) on ASLT line board. Primarily to compensate for long wires. Dial: 783 + digit 0-9. Default level is 3.


The ASLT output level can also be set from the Users & Stations menu in AlphaPro. As from AMC ver. 11.2.3.x the relation between the 783 volume setting and AlphaPro setting is as follows:

          $VOL /
AlphaPro  783+n  IP-station  DIP  NVRAM
--------  -----  ----------  ---  -----
 -14        0       1         0    242
 -12                               244    
 -10                               246
  -8        1       2         4    248
  -6                               250
  -4        2       3         9    252
  -2                               254
   0        3       4        13      0
   2        4                        2
   4        5       5        18      4
   6        6                        6
   8        7       6        22      8
  10                                10
  12        8       7        27     12
  14                                14 
  16        9       8        31     16


Versions prior to AMC 11.2.3.x:

AlphaPro  783+n  IP-station
--------  -----  ----------
 -14        0        
 -12	            1
 -10	             
  -8        1       2
  -6	             
  -4        2       3
  -2	             
   0        3       4
   2        4        
   4        5       5
   6        6        
   8        7       6
  10	             
  12        8       7
  14	             
  16        9       8

Related AlphaCom Data Protocol message: VOL