Difference between revisions of "Open / Private selection feature"
From Zenitel Wiki
Line 2: | Line 2: | ||
|- | |- | ||
|width="170pt"|'''Feature''': | |width="170pt"|'''Feature''': | ||
− | | | + | | Programmable Open/Private |
|- | |- | ||
|'''Default directory number''': || 7886, 7887 | |'''Default directory number''': || 7886, 7887 | ||
Line 10: | Line 10: | ||
|'''Parameter 1''': || 0 = Open (7886)<br> 1 = Private (7887) | |'''Parameter 1''': || 0 = Open (7886)<br> 1 = Private (7887) | ||
|-valign="top" | |-valign="top" | ||
− | |'''Description''': || Feature for | + | |'''Description''': || Feature codes for setting the station in Open or Private mode. To use these codes, the station must first be enabled for this feature in AlphaPro, Users & Stations -> Station Type -> Programmable Open/Private. |
− | + | ||
− | + | Additional information: | |
− | + | * By default the Open/Private status is decided by the station hardware by means of a Open/Private switch on the station. | |
+ | * Alternative to mechanical PRIVATE switch. | ||
+ | |||
+ | |||
|} | |} | ||
− | + | ||
Procedure: Dial 7886. If the feature is allowed, a success tone is heard, else a failure tone. The setting is permanent (stored in NVRAM, survives reset). | Procedure: Dial 7886. If the feature is allowed, a success tone is heard, else a failure tone. The setting is permanent (stored in NVRAM, survives reset). | ||
Configuration: There is a flag in AlphaPro that decide if this station's OPEN/PRIVATE status is controlled by feature codes OR by station hardware. (User/More../Programmable Open/Private). | Configuration: There is a flag in AlphaPro that decide if this station's OPEN/PRIVATE status is controlled by feature codes OR by station hardware. (User/More../Programmable Open/Private). | ||
Line 26: | Line 29: | ||
Alternative way to select call mode PRIVATE. | Alternative way to select call mode PRIVATE. | ||
Procedure: Dial 7887. If the feature is allowed, a success tone is heard, else a failure tone. The setting is permanent (stored in NVRAM, survives reset). | Procedure: Dial 7887. If the feature is allowed, a success tone is heard, else a failure tone. The setting is permanent (stored in NVRAM, survives reset). | ||
− | + | (User/More../Programmable Open/Private). | |
Application: | Application: | ||
• Fixed functionality often required, where the station must ignore the PRIVATE switch. | • Fixed functionality often required, where the station must ignore the PRIVATE switch. |
Revision as of 22:28, 28 January 2008
Feature: | Programmable Open/Private |
Default directory number: | 7886, 7887 |
Feature number: | 80 |
Parameter 1: | 0 = Open (7886) 1 = Private (7887) |
Description: | Feature codes for setting the station in Open or Private mode. To use these codes, the station must first be enabled for this feature in AlphaPro, Users & Stations -> Station Type -> Programmable Open/Private.
Additional information:
|
Procedure: Dial 7886. If the feature is allowed, a success tone is heard, else a failure tone. The setting is permanent (stored in NVRAM, survives reset). Configuration: There is a flag in AlphaPro that decide if this station's OPEN/PRIVATE status is controlled by feature codes OR by station hardware. (User/More../Programmable Open/Private). Application: • Fixed functionality often required, where the station must ignore the PRIVATE switch. • EMC problems with PRIVATE switch in wall stations. Now solved by removing the switch, and use keypad for PRIVATE mode. Version: AMC 06.00 DirNo: 7886 Feature: 80/0 (Db ref. 587) 3.1.7. Feature idle: Set station PRIVATE Alternative way to select call mode PRIVATE. Procedure: Dial 7887. If the feature is allowed, a success tone is heard, else a failure tone. The setting is permanent (stored in NVRAM, survives reset).
(User/More../Programmable Open/Private).
Application: • Fixed functionality often required, where the station must ignore the PRIVATE switch. • EMC problems with PRIVATE switch in wall stations. Now solved by removing the switch, and use keypad for PRIVATE mode.
80 FEAT_OPEN_PRIVATE
Param1 | Description |
---|---|
?? | Toggle functional OPEN/PRIVATE on station |
Alternative to mechanical PRIVATE switch.
Mode 0 = OPEN. Mode 1 = PRIVATE (must be enabled per station). |