Difference between revisions of "Add new ASVP alarm messages (MDF)"
From Zenitel Wiki
(New page: * The ASVP board can store a large number of alarm messages. In the MDF file there is mapping information saying which alarm message in the ASVP corresponds to which alarm message id in AM...) |
|||
Line 3: | Line 3: | ||
* Before you go on, make a backup of your mdf file. In the directory AlphaPro -> Exchgs -> your exchange you will find a file with the extension .mdf. Make a backup copy of the file. | * Before you go on, make a backup of your mdf file. In the directory AlphaPro -> Exchgs -> your exchange you will find a file with the extension .mdf. Make a backup copy of the file. | ||
* The different alarm messages are defined in a table in the ASVP. | * The different alarm messages are defined in a table in the ASVP. | ||
− | {| | + | |
+ | |||
+ | {| border="1" align=left | ||
|- | |- | ||
− | |width=" | + | |width="50pt"|Directory number |
− | |width=" | + | |width="50pt"|Alarm message id: |
− | |width=" | + | |width="50pt"|Group, individ: |
|- | |- | ||
|8191|| 1 || 4, 10 | |8191|| 1 || 4, 10 | ||
Line 42: | Line 44: | ||
|- | |- | ||
|} | |} | ||
+ | |||
+ | <pre> | ||
+ | %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% | ||
+ | % % | ||
+ | % New group: ANNOUNCEMENT = 30 (No text) % | ||
+ | % % | ||
+ | %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% | ||
+ | |||
+ | #UMSG 30 1 (4,10) | ||
+ | #UMSG 30 2 (4,11) | ||
+ | #UMSG 30 3 (4,13) | ||
+ | #UMSG 30 4 (4,14) | ||
+ | #UMSG 30 5 (4,15) | ||
+ | #UMSG 30 6 (4,16) | ||
+ | #UMSG 30 7 (4,17) | ||
+ | #UMSG 30 8 (4,18) | ||
+ | #UMSG 30 9 (4,19) | ||
+ | </pre> |
Revision as of 10:54, 10 August 2007
- The ASVP board can store a large number of alarm messages. In the MDF file there is mapping information saying which alarm message in the ASVP corresponds to which alarm message id in AMC. As a default 9 alarm messages are mapped in the MDF file.
- When using ASVP board with more than 9 alarm messages the MDF file needs to be modified
- Before you go on, make a backup of your mdf file. In the directory AlphaPro -> Exchgs -> your exchange you will find a file with the extension .mdf. Make a backup copy of the file.
- The different alarm messages are defined in a table in the ASVP.
Directory number | Alarm message id: | Group, individ: |
8191 | 1 | 4, 10 |
8192 | 2 | 4, 11 |
8193 | 3 | 4, 13 |
8194 | 4 | 4, 14 |
8195 | 5 | 4, 15 |
8196 | 6 | 4, 16 |
8197 | 7 | 4, 17 |
8198 | 8 | 4, 18 |
8199 | 9 | 4, 19 |
4, 20 | ||
4, 21 | ||
4, 22 | ||
4, 23 | ||
4, 24 | ||
4, 25 | ||
4, 26 |
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% % % % New group: ANNOUNCEMENT = 30 (No text) % % % %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% #UMSG 30 1 (4,10) #UMSG 30 2 (4,11) #UMSG 30 3 (4,13) #UMSG 30 4 (4,14) #UMSG 30 5 (4,15) #UMSG 30 6 (4,16) #UMSG 30 7 (4,17) #UMSG 30 8 (4,18) #UMSG 30 9 (4,19)