Difference between revisions of "CDC CMD"
From Zenitel Wiki
Line 37: | Line 37: | ||
101 OUT_OF_SERVICE, lost contact with Network Disk <br> | 101 OUT_OF_SERVICE, lost contact with Network Disk <br> | ||
102 ACTIVE_TIMEOUT, failed to receive ACTIVE from AMCD, Billing charge stops, ABSD FSM terminates <br> | 102 ACTIVE_TIMEOUT, failed to receive ACTIVE from AMCD, Billing charge stops, ABSD FSM terminates <br> | ||
− | 103 | + | 103 ESTABLISHED_TIMEOUT <br> |
− | |||
|- | |- | ||
|align=center|5||[[UINT1]]||colspan="3"|number of digits to delete from out-buffer | |align=center|5||[[UINT1]]||colspan="3"|number of digits to delete from out-buffer |
Revision as of 13:05, 14 August 2008
Related to ABSD_Billing
CDC_CMD | 0x009F | 159 | AMC 10.40 | |
---|---|---|---|---|
Message used for billing control. <br\>
Call Detail Control message, response to CDC_STATE. command. Used from ABSD towards AMCD | ||||
1 | UINT2 | Connection Reference for this "dialing" sequence (actually ST_IND of A-station). | ||
2 | NET_OBJ_REF | A-station (billed station) . | ||
3 | UINT1 | Command 1 DIAL_PIN, (dial pin code , display *) | ||
4 | UINT1 | ABORT reason codes [1..99] ABSD expects immediate DISCONNECT from AMCD 1 NO_BILLING_LICENSE ABORT information codes [101..199] 101 OUT_OF_SERVICE, lost contact with Network Disk | ||
5 | UINT1 | number of digits to delete from out-buffer | ||
6 | NET_OBJ_REF | For TRUNK_SET: Trunknumber | ||
7 | TEXT16 | Additonal info as text (Abort reason, user name). |