Actions

2-3c. SIP trunk with MP114 (solution)

From Zenitel Wiki

Revision as of 12:31, 28 October 2015 by Asle (talk)
System configuration


AlphaWeb Configurations

Assign IP adress to the AlphaCom XE Ethernet port(s)

  • Log on to AlphaWeb and enter a valid IP address on the Ethernet port.

In the example below, Ethernet port 1 is used. Consult your network administrator to obtain the IP address.

System Configuration - Interface.PNG

Insert SIP Trunk licenses

Log on to AlphaWeb and install the SIP Trunk license.

Insert License.PNG

Firewall (filter) settings

Enable the SIP protocol and VoIP Audio on the desired Ethernet port (default enabled for Ethernet port1).

System Configuration - Filters.PNG

AlphaPro Configuration

Create a SIP Trunk Node

From the AlphaPro main menu, use the ‘+’ button next to the ‘Select Exchange’ dropdown list to create a new exchange. The exchange type must be set to ‘SIP Node’.

Set the parameters as follows:

Create a SIP Trunk Node.jpg

The SIP Trunk IP address must be identical to the IP address of the SIP Gateway.

Note: If the AlphaCom is configured with a SIP Registrar node in addition to the SIP Trunk node, the SIP Registrar node must have a lower node number than the SIP Trunk node.

Define the AlphaCom / SIP routing

In Exchange & System > Net Routing use the Insert button to create a route between the AlphaCom and SIP Gateway. Set Preferred codec to G711u and RTP Packet Size to 20 ms.

Define the AlphaCom , SIP routing.jpg

Create Prefix number

The directory number (prefix) used to access the telephone line must be programmed in the AlphaCom directory table with feature 83 and Node = SIP Trunk node number (100 in this example). In the example below the default directory number 0 has been modified to be used as a prefix.

Create Prefix number.jpg

Update the exchange

Log on to the exchange and update the exchange by pressing the SendAll button. Reset the exchange after the send operation is finished.