Actions

INCA Substation LED Indicators

From Zenitel Wiki

Revision as of 13:22, 21 October 2016 by Roarl (talk) (8022 - IP Substation)

8022 - IP Substation

Indications

Station LED (on board and front plate)

Station LED


Station LED


Blinking at 1 second intervals:

  • Station has no connection to the AlphaCom XE Audio Server.

Possible reasons:

  • No connection to Ethernet
  • Wrong AlphaCom IP address configured
  • Invalid IP address
  • No gateway or wrong gateway to the AlphaCom XE Audio Server

Blinking at 5 second intervals:

  • Station connected but NOT registered in the AlphaCom XE Audio Server.

Reason:

  • Station has not been programmed in AlphaPro
  • Missing IP Station license in AlphaCom XE Audio Server

No blinking:

Possible reasons:

  • Station connected and registered to the AlphaCom XE Audio Server
  • Station not powered up (if no other LEDs are active)

Status LED

Bicolor SMD LED on board component side.

Status LED


Blinking 2 red + 1 green:

  • Station has no connection to the AlphaCom XE Audio Server.

Blinking 1 red + 2 green:

  • Station connected but NOT registered in the AlphaCom XE Audio Server.

Blinking 3 green:

  • Station connected and registered in the AlphaCom XE Audio Server.

LAN LEDs

Left LED:

Left LED


  • Steady light: Ethernet connection OK
  • Blinking: Ethernet traffic
  • No light: No Ethernet connection

Right LED:

Right LED


  • Light: 100 Mbit Ethernet connection