This procedure is applicable for the IP Hotline Station.

Procedure:
This procedure will load factory defalt settings in the station. The unit can be set to use either Static IP or DHCP.

  1. Lift the handset, and power up the station.
  2. Replace the handset after exactly 2 flashes of the station LED.
  3. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then lift the handset again.
  4. Keep the handset lifted until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  5. Replace the handset and the station will restart with the factory default settings.
IP Hotline Station LED 2.PNG


Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 (Static) or DHCP
  • Username: admin
  • Password: alphaadmin