Actions

TCAS Connections

From Zenitel Wiki

Revision as of 12:30, 16 August 2018 by Asle (talk | contribs)
AlphaCom icon 300px.png
TCAS substation - Rear side

This article describes connection details of the analog intercoms TCAS-1, TCAS-2 and TCAS-3.

Wiring

The cabling from the AlphaCom server to the intercom station is star wiring. Two twisted pairs of wires are required. The maximum distance depends on the cable diameter:

  • 0.5 mm wires: 1.4 km
  • 0.6 mm wires: 2.0 km
  • 0.9 mm wires: 4.0 km

The station line is connected to the station by means of an RJ45 connector at the rear side of the station, or optional by using the plugable screw connector.

WiringAnalogTCAS.png


Note icon The station cable is not a 1:1 cable!


For details on connection at the AlphaCom server side, see ASLT - AlphaCom Subscriber Line Board


Second Call Key

The station is prepared for a future second call key (DAK2).

This second call key can be found on the print if wanted and utilized with an external call button.

TCAS Connections 2.PNG


  • A second external call key must be connected between the A-wire and the lower leg on D6 (highlighted in the image above).