Initial Setup

The ECP-AA1 is delivered with factory default settings. By default, the unit's IP settings are configured according to DHCP.

To configure the unit:

  • Press the call button on the unit for it to speak its IP address.
  • Ensure that the IP address of your PC is in the same range as that of the station IP
  • Access the station by logging into the web interface using a standard web browser on a PC
  • In the browers address bar, enter the station IP address and press ENTER key. The station login page will be displayed.
  • Click Login
  • Enter the default User name: admin
  • enter the default Password: alphaadmin
  • Select Station Main > Main Settings
ECP-AA1 config SIP 1.png


  • Under Station Mode select Use SIP
  • Under Product Model And Accessory select Kit
  • Depending on system requirements, set the IP Settings to DHCP or Static IP. In the latter case, fill in the network details as required.
  • Click Save
  • On the new page, click Apply

The unit will now reboot.

Audio Settings

Normally no changes are required to be made to the audio settings, but depending on the specific circumstances where the unit is installed, minor adjustments may be needed.

  • Select SIP Configuration > Audio Settings
ECP-AA1 config SIP 2.png


On this page it is possible to set:

  • Speaker Volume
  • Microphone Sensitivity
  • Noise Reduction Level

Furthermore, it is possible to select different algorithms for the Conversation Mode.

Note icon Due to the close proximity of the microphone and speaker it may be necessary to select Robust Duplex as Conversation Mode if either the speaker level or the microphone sensitivity is increased from the default setting.


I/O Settings

Select SIP Configuration > I/O Settings

PICTURE

Under Configuration set the following values for the I/O Pins: - I/O Pin 1: Input 1 - I/O Pin 2: Input 2 or Output 2 – depending on the application for which this I/O will be used - I/O Pin 3: Input 3 or Output 3 – depending on the application for which this I/O will be used - I/O Pin 4: Input 4 - I/O Pin 5: Output 5 - I/O Pin 6: Output 6

Click Save

Although the ECP-AA1 will not use these settings until after a reboot, it is not necessary to reboot at this stage.

Output Settings

Select SIP Configuration > Relay Settings

CCTV Interface

For Choose Relay To Configure: Select Relay 1

PICTURE

Under Configuration set the following values: - Outgoing Ringing: On - Idle: Off • Click Save

General Settings

For Choose Relay To Configure: Select Output 5

PICTURE

Under Configuration set the following values: - Outgoing Ringing: Slow flash - Outgoing Call: Off - Idle: Off • Click Save

For Choose Relay To Configure: Select Output 6

PICTURE

Under Configuration set the following values: - Outgoing Call: On - Idle: Off • Click Save

Call Buttons

Both the call button on the unit and the emergency break input are set up as a call button. Select SIP Configuration > Direct Access Key Settings

PICTURE

Assuming that the call button should call a fixed number: • Enter the number to be called in the field Value for both Input 1 and Input 4 • Make certain that the Function (in call) settings for both inputs are set to Do Nothing • Click Save

Ringlist Settings

Optionally it is possible to make the ECP-AA1 call numbers in sequence until the call is accepted. If this is the requirement, make the settings as shown below: