Modify ASVP alarm message repetitions
From Zenitel Wiki
By default the ASVP alarm messages are repeated endlessly, but for some applications it is required that the message is played once or a few times and then stop. For each alarm message there is a parameter that controls the number of repetitions. As this parameter is not available from AlphaPro, it has to be changed directly in the AMC memory, using the nvram editor in the TST console or the $SNV command from the Event Handler.
NOTE: Before continuing it is highly recommended to do a backup of AMC memory to Flash. Dial 7820+M from a SuperUser station.
Procedure
- From the nvram editor in the TST-console, go to:
.ex_mi.announce_tab[n].repeat
where n = message number.
Set number of repetitions of the alarm message (1 to 255, 255 is endless)
Example
Using the TST Console
Changing the parameter for alarm message 1 (Directory number 8191) to play once, then stop.
Start the TST Console, then:
Type: | Explanation |
---|---|
nvram <Enter><Enter> | Start the nvram editor from the TST console |
2 <Enter> | Enter line 2: .ex_mi… |
2 <Enter> | Enter line 2: .ex_mi_announce_tab[81] |
1 <Enter> | Select alarm message number 1 (*) |
3 <Enter> | Enter line 3: ….tab[1].repeat = 255 |
1 <Enter> | Set number of repetitions of alarm message, here 1 |
Q <Enter> | Exit NVRAM table, and save changes |
(*) Use message number 2 - 9 for the messages 8192 - 8199.
Using the Event Handler
This example shows how to change the parameter for alarm message 1 (Directory number 8191) to play once, then stop:
(*) Use message number 2 - 9 for the messages 8192 - 8199.