Device
From Zenitel Wiki
All data messages are addressed to a device. A device is always related to (owned by) a node. A full device address consists of <node> <device>.
<Device> is one byte.
Note that devices can both be physical boxes (e.g. RIO) or a function (Router).
Value (decimal) | Value (Hex) | Device Function |
---|---|---|
0 | 0x00 | Invalid device (reserved NULL value) |
PIN_COUNTS | Response to the GET_PIN_COUNTS message | |
SET_RCO | Turn the given remote control output on | |
SET_RCO_OK | Positive response to the SET_RCO message | |
SET_RCO_FAILED | Negative response to the SET_RCO message | |
CLEAR_RCO | Turn the given remote control output off | |
CLEAR_RCO_OK | Positive response to the CLEAR_RCO message | |
CLEAR_RCO_FAILED | Negative response to the CLEAR_RCO message | |
PULSE_RCO | Generate a pulse with the defined length | |
PULSE_RCO_OK | Positive response to the PULSE_RCO message | |
PULSE_RCO_FAILED | Negative response to the PULSE_RCO message | |
POLL_RCI | Poll the given remote control input once | |
SCAN_RCI_ONCE | Scan input until defined condition is met, then report to exchange | |
SCAN_RCI_ACK | Positive response to the SCAN_RCI_ONCE message | |
RCI_IS_ON | Response to the POLL_RCI and SCAN_RCI_ONCE messages, input pin is on | |
RCI_IS_OFF | Response to the POLL_RCI and SCAN_RCI_ONCE messages, input pin is off | |
SCAN_END_ACK | Acknowledgment to the RCI_IS_OFF and RCI_IS_ON messages |