Actions

VPA-400

From Zenitel Wiki

Revision as of 15:10, 23 September 2009 by Roarl (talk) (Specifications)
VPA-120.PNG

Features

  • 400 W power amplifi er in a 19” rack housing
  • 100 V and 8 ohm output
  • Dual inputs with priority switching
  • Temperature controlled, forced back-to-front ventilation
  • 115/230 VAC mains and 24 VDC battery backup
  • Pilot tone signal path supervision
  • 24 VDC / 800 mA power output for external equipment
  • Chime signal with on/off switch

Description

The STENTOFON VPA power amplifier is originally designed for use on ships, which means it is very robust and can handle mobile environments as well as stationary temperature controlled rooms. The amplifier has to be installed in a 19” rack and occupies 3 HU with addition of a 1 HU ventilation grid. The amplifier is protected against overload and short circuits. A temperature controlled fan ensures high reliability at high output level and low ventilation noise at lower output levels. The amplifier operates on 115/230 VAC mains with option for automatic switching to a 24 VDC battery backup in case of power failure. The amplifier is supervised by a pilot tone to continuously check the signal path, and a fault will be reported by an indicator in front combined with a closing contact for external fault warning. The amplifier has a built in selectable chime generator activated by a priority switch to give an alert signal before the announcement.

Specifications

style="background:#ffdead;" width="250" System style="background:#ffdead;" width="70" Size (kB)
Colouor Black
Dimensions (W x H x D) 482 x 133 x 420 mm
Weight 27.4 kg
Power Supply 115/230 VAC +/-10%, 50/60 Hz, 390W
24 VDC +/-25%, - max 15.4 A
Operating Temp. -15°C <-> +55°C
Relative humidity < 95%
Output 100 V, 8 ohm - 400 W
Requency Response 50 Hz - 20 kHz +/-3dB

Related Articles

VPA - Public Address Amplifiers