Actions

CDC CMD

From Zenitel Wiki

Revision as of 13:05, 14 August 2008 by Arild (talk)

Related to ABSD_Billing

CDC_CMD 0x009F 159 AMC 10.40
Message used for billing control. <br\>

Call Detail Control message, response to CDC_STATE. command. Used from ABSD towards AMCD

1 UINT2 Connection Reference for this "dialing" sequence (actually ST_IND of A-station).
2 NET_OBJ_REF A-station (billed station) .
3 UINT1 Command

1 DIAL_PIN, (dial pin code , display *)
2 DIAL_NORMAL
3 TRUNK_SET, Set trunk number for SIP, start SIP connection.
4 ABORT, see reason codes in [4]. Expect CDC_STATE(DISCONNET) in return
5 LOW_BALANCE, 10 seconds to ABORT due to ACCOUNT_OVERDRAWN

4 UINT1 ABORT reason codes [1..99]

ABSD expects immediate DISCONNECT from AMCD

1 NO_BILLING_LICENSE
2 INVALID_PIN_CODE
3 BARRED_NUMBER
4 ACCOUNT_OVERDRAWN
5 MISSING_TRUNK_DATA
6 BACKUP_IN_PROGRESS

ABORT information codes [101..199]
ABSD may or may not continue Billing charge process with local FSM data

101 OUT_OF_SERVICE, lost contact with Network Disk
102 ACTIVE_TIMEOUT, failed to receive ACTIVE from AMCD, Billing charge stops, ABSD FSM terminates
103 ESTABLISHED_TIMEOUT

5 UINT1 number of digits to delete from out-buffer
6 NET_OBJ_REF For TRUNK_SET: Trunknumber
7 TEXT16 Additonal info as text (Abort reason, user name).

Back to AlphaNet message list