Actions

Play DAK Feature

From Zenitel Wiki

Revision as of 21:28, 15 April 2019 by Asle (talk | contribs) (Restriction)
AlphaCom icon 300px.png

Programming of DAK sequences with single digit dialing and wait states

Available from AMC 10.50

Play DAK programmed from DAK string

By using the DAK "T" parameter in the beginning of the DAK string, a 18 digit string can be programmed.

Sequence syntax:

0-9    Digits
# *    Signaling available during trunk connection
w      Pause for 0,5 Second 
W      Pause for 1 Second 

Example DAK string as programmed in AlphaPro:
AlphaPro Play DAK


Description:
Get line out "01"
Wait 1 Sec
Dial Tellog pin code "123#"
Wait 2 Sec
Dial Zenitel "40002500".

Timing of play speed

Default digit step time is 200 ms. Configurable from NVRAM:

85 &000874 .ex_profile.timeouts.play_dak_time = 2 (0x0002) 


Play DAK by Data Protocol

If longer strings are needed the Station DAK key as RCI event trigger can be used for sending the PLAY_DAK ($PD) data protocol message.

Restriction

Maximum 50 simultaneous DAK Play functions can be activated at the same time in one node.