TCAS Dimensions & Mounting Instructions
From Zenitel Wiki
Dimensions (WxHxD) | Weight | Partnumber | |
TCAS1 | 180 x 120 x 54 mm | 0.8 kg | 1008114010 |
TCAS1 after flushmount | 180 x 120 x 20 mm | - | - |
TCAS1 with onwall box | 180 x 120 x 82 mm | - | - |
TCAS2 | 180 x 120 x 54 mm | 1.0 kg | 1008114020 |
TCAS2 after flushmount | 180 x 120 x 20 mm | - | - |
TCAS2 with onwall box | 180 x 120 x 82 mm | - | - |
TCAS3 | 180 x 120 x 54 mm | 0.8 kg | 1008114030 |
TCAS3 after flushmount | 180 x 120 x 20 mm | - | - |
TCAS3 with onwall box | 180 x 120 x 82 mm | - | - |
Contents
TCAS Compact Station Dimensions
Onwall Surface Mounting
On-Wall Surface Mount Back Box - TA-1
Mounting holes are to be drilled as shown.
Max. recommended screw diameter: ISO M6 or ANSI 1/4". Screw length must be greater than 25 mm or 1". A4 stainless steel socket head screws/bolts are recommended. Max. recommended screw head diameter: 9.5 mm or 3/8".
Optional nylon washers for extra protection against corrosive effects between surfaces are provided. They should be placed at the bottom of the mounting holes. Grommets and an M20 cable gland are provided.
On-Wall Surface Mounting Procedure
- 1. Mount the back box onto the wall
- 2. Fit the gasket onto the back box with the ridged side facing down
- –Plug the AlphaCom cable into the RJ-45 port on the station
- 3. Mount the Turbine station onto the back box with the M5 fasteners provided
Note! Use the grommets and M20 cable gland provided for the cable holes on the back box