Actions

IP Flush Master and Headset

From Zenitel Wiki

Revision as of 12:42, 6 January 2015 by Asle (talk)

This article describes how to connect headset to the IP Flush Master - 1008031000.


Handset module 1008071000 for IP Flush Master

There are two main hardware revisions of the Handset 1008071000 for IP Flush Master stations. Compatibility with the IP Flush Master station is as follows:

Handset revision 1008071000.0300 or newer (from May 2013)

  • Used with IP Flush Master revision 1008031000.0400 or newer: The handset is directly compatible with the IP Flush Master. Connect the handset to the handset connector of the station.
  • Used with IP Flush Master revision 1008031000.0301 or older:
  • Update the software of the IP Flush Master to version 02.3.3.1 or later
  • Log on to the StationWeb. In Advanced Configuration -> Audio, enable the flag “Handset in Headset Slot”
How to enable the flag “Handset in Headset Slot” in Advanced Configuration -> Audio


  • Connect the Handset to the HEADSET-connector of the station

Handset revision 1008071000.0201 or older

  • Used with IP Flush Master revision 1008031000.0301 or older: The handset is directly compatible with the IP Flush Master. Connect the handset to the handset connector of the station.
  • Used with IP Flush Master revision 1008031000.0400 or newer:
  • Upgrade the handset to revision 0300 by dismantling the handset by unscrewing the two screws, flip the circuit board over and solder a strap as shown in the image.
Upgrade the handset to version 0300 by adding a strap


  • Connect the handset to the handset connector of the station.

About noise in the ear-piece of the handset

When handset revision 1008071000.0201 or older is used with IP Flush Master revision 1008031000.0301 or older, one might experience noise in the ear-piece of the handset. This can be improved by upgrading the handset to revision 1008071000.0300, and use the headset connector of the station.

Procedure:

  • Dismantle the handset by unscrewing the two screws
  • Flip the circuit board over and solder a strap as shown in the image
  • Update the software of the IP Flush Master to version 02.3.3.1 or later
  • Log on to the StationWeb. In Advanced Configuration -> Audio, enable the flag “Handset in Headset Slot”
  • Connect the handset to the HEADSET-connector of the station


NOTE: The option to use the headset input also for handset is a workaround available in AlphaCom-mode only.