Actions

TouchLine Key Signaling

From Zenitel Wiki

Revision as of 20:57, 24 May 2007 by Asle (talk) (Optional DAK Acknowledge)

Signaling protocol

The analog station interface uses two types of signaling protocols, Current Signaling and Tone Signaling

Current Signaling

The a/b-wires are the loudspeaker wires, and the c/d-wires are the microphone and digit selection wires. Approximate current values are (the currents in a/b-wires for display station is shown in brackets):

a/b-loop:

  • On-hook: 3mA (13 mA)
  • Off-hook: 0 mA (10 mA)
  • M-Key: 10 mA (20 mA)
  • C-key: 20-25 mA (30-35 mA)

c/d-loop:

  • ID (key press): 10 mA
  • Open: < 1 mA
  • Private: 3 mA

Digit Signaling

Station keyboard digits 0 - 9 use sinewave tones in the range 500Hz to 2300 Hz, at 200 Hz steps.

  • Digit 0: 500 Hz
  • Digit 1: 700 Hz
  • Digit 2: 900 Hz
  • Digit 3: 1100 Hz
  • Digit 4: 1300 Hz
  • Digit 5: 1500 Hz
  • Digit 6: 1700 Hz
  • Digit 7: 1900 Hz
  • Digit 8: 2100 Hz
  • Digit 9: 2300 Hz

Extended Digit Signaling

In addition to the keyboard digits 0 - 9 another set of 10 tones are used for DAK signaling for CRM IV, Dual Display and PrisCom stations.

These tones 10-19 are sinewave tones in the range 600Hz to 2400 Hz, at 200 Hz steps.

DAK Signaling

DAK (Direct Access Key) is the speed-dial buttons on the station.

Master station DAK keys use a combination of current signaling (M) and digits:

  • DAK 1: M + digit 0
  • DAK 2: M + digit 1
  • DAK 3: M + digit 2
  • DAK 4: M + digit 3
  • DAK 5: M + digit 4
  • DAK 6: M + digit 5
  • DAK 7: M + digit 6
  • DAK 8: M + digit 7
  • DAK 9: M + digit 8
  • DAK 10: M + digit 9

When "Hot-Line" function is enabled, Off-Hook is mapped to DAK 7 and On-Hook to DAK 8.


CRM IV and Dual Display Stations also use a combination of current signaling and digits:

  • D1-D10: M+0 - M+9
  • D11-D20: digit 10-19
  • D21-D30: M+10 - M+19
  • D31-D40: C+0 - C+9
  • D41-D50: C+10 - C+19
  • D51-D60: (Prefix +) M+0 - M+9
  • D61-D70: (Prefix +) digit 10-19
  • D71-D80: (Prefix +) M+10 - M+19
  • D81-D90: (Prefix +) C+0 - C+9
  • D91-D100: (Prefix +) C+10 - C+19

Prefix = ID+C


Priscom Stations use so called Two Tone DAK Signaling which is a combination of Extended Digit Signaling and Digit Signaling:

  • Key board digit 0-9: Digit Tone 0-9
  • DAK D1-D15: Digit tone 10 + 0 to 10 + 14
  • DAK D16-D30: Digit tone 11 + 0 to 11 + 14
  • DAK D31-D45: Digit tone 12 + 0 to 12 + 14
  • DAK D46-D60: Digit tone 13 + 0 to 13 + 14
  • DAK D61-D75: Digit tone 14 + 0 to 14 + 14
  • DAK D76-D90: Digit tone 15 + 0 to 15 + 14
  • DAK D91-D100: Digit tone 16 + 0 to 16 + 9


Substations use current signaling only:

  • DAK 1: ID
  • DAK 2: ID + M
  • DAK 3 ID + LT (off-hook)

Optional DAK Acknowledge

A station using Two Tone DAK Signaling can be configured with acknowledge on DAK keys:

  • The AMC application will send an acknowledge message by the Display Text Protocol.
  • The station will acknowled this by sending tone 18.