CALL SETUP

From Zenitel Wiki

Revision as of 10:00, 11 June 2007 by Hege (talk)
CALL_SETUP 0x0008 8 AMC 08.20
$CALL L101 L102 <br\> $CALL L101 L102 W32 <BR\> $CALL L101 L102 W64 Let 101 call 102 <BR\> Let 101 call, ignore if 102 forwards <br\> Let 101 call 102, force both 101 and 102
Set the timer of a mail queue entry. <BR\> When timeout, the event MAIL_TIMEOUT is generated. 10 seconds later the mail queue entry will be deleted automatically. (All new mails are initialized by the AMC to max timer.)
1 NET_OBJ_REF {ECL_STATION} Station.
2 UINT2 Mail tag (unique id) for current queue entry.
3 UINT4 Timeout value in seconds.<BR\>- The timer is ticked every 10 seconds. This means that the minimum timer value is 10 seconds, and longer times should be specified with last digit 0.<BR\>- The longest possible time is 655350 seconds, which is 7.5 days <BR\>- The system guarantees a minimum timeout as specified, worst case 10 seconds later. Ex: setting 60 seconds generates timeout 60 - 69 seconds later.
Response: COMMAND_RESPONSE