CALL_SETUP | 0x0008 | 8 | AMC 08.20 | |
---|---|---|---|---|
$CALL L101 L102 <br\> $CALL L101 L102 W32 <BR\> $CALL L101 L102 W64 | Let 101 call 102 <BR\> Let 101 call, ignore if 102 forwards <br\> Let 101 call 102, force both 101 and 102 | |||
$CALL_SETUP sets up a conversation like dialing from a station. Default behavior:
$CONN_REQUEST/$CONN is retained for compatibility only, DPMT_CALL_SETUP is the preferred message now. | ||||
1 | NET_OBJ_REF {ECL_STATION} | Station. | ||
2 | UINT2 | Mail tag (unique id) for current queue entry. | ||
3 | UINT4 | Timeout value in seconds.<BR\>- The timer is ticked every 10 seconds. This means that the minimum timer value is 10 seconds, and longer times should be specified with last digit 0.<BR\>- The longest possible time is 655350 seconds, which is 7.5 days <BR\>- The system guarantees a minimum timeout as specified, worst case 10 seconds later. Ex: setting 60 seconds generates timeout 60 - 69 seconds later. | ||
Response: | COMMAND_RESPONSE |