AlphaCom supervision of protocol converter daemons
From Zenitel Wiki
Revision as of 03:21, 25 May 2007 by Aksel (talk) (New page: SIPD and RMD are connected to AMCD through local sockets using Stentofon Simple Link Layer *The daemons sends Idle frames every 5? second. *If no idle frame is received from the d...)
SIPD and RMD are connected to AMCD through local sockets using Stentofon Simple Link Layer
- The daemons sends Idle frames every 5? second.
- If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using:
- /opt/amc/script/rmd stop
or
- /opt/amc/script/sipd stop
- 5 seconds later the deamon is restarted by AMCD using:
- /opt/amc/script/rmd start
or
- /opt/amc/script/sipd start
- If no idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this will be done 5 times.