AlphaCom supervision of protocol converter daemons
From Zenitel Wiki
SIPD and RMD are connected to AMCD through local IP sockets using Stentofon Simple Link Layer
SIPD is connected to ACDP port 31 RMD is connected to ACDP port 32
- The daemon send an idle frame to AMCD every 5? second.
- If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using:
/opt/amc/script/rmd stop or /opt/amc/script/sipd stop
- 5 seconds later the deamon is restarted by AMCD using:
/opt/amc/script/rmd start or /opt/amc/script/sipd start
- If no new idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this sequence will be repeated 5 times.
Example of Syslog AlphaLog report for this sequence:
W(204.65) INFO_DP_LINK_DOWN, no:337 "" P1: 31, P2: 150, P3: 0 DP link down, port 31 node 150 device 0 W(204.65) UNEXP_SIG, no:338 "sipd start" P1: 31, P2: 0, P3: 0 W(204.65) INFO_DP_IDLE_FRAME, no:339 "" P1: 31, P2: 150, P3: 0 Peer on ACDP port 31 is node 150 device 0