Actions

VPA - Public Address Amplifiers

From Zenitel Wiki

Revision as of 14:48, 28 November 2008 by Roarl (talk) (Power)

Introduction

About this document

This manual is intended to give relevant information on the system features, available equipment, typical configurations, simplified wiring and programming and technical data for the concept.
This document is aimed at:

  • Consultans
  • Installers
  • End users

Equipment covered by this document

Public adress amplifiers:

  • VPA-120 (120 W)
  • VPA-240 (240 W)
  • VPA-400 (400 W (*1))

Note! The amplifiers are delivered for 230 VAC as standard. For 115 VAC mains, a plug must be removed and fuses must be changed. See section 3.3.4.

Rules and regulations

The VPA system and its components have been tested according to the following regulations:

  • EN 60065: 2002
“Audio, video and similar electronic apparatus. Safety requirements”
  • IEC 60533: Second edition, 1999
"Electrical and electronic installation in ships - Electromagnetic compatibility".
  • EN 60945: Fourth edition, 2002
"Maritime navigation and radio communication equipment and systems - General requirements - Methods of testing and required test results".
  • IACS E10: Corr.1 July 2003
"Unified environmental test specifications - Testing procedure for electric control and monitoring, safety and protection, onboard computer based systems and peripherals, loading instruments, internal communication and other electrical equipment as considered appropriate".

Publication log

v.1.0 - Sep. 2007

CONNECTORS AND CONTROLS

VPA-120 Front Panel
VPA-120 Rear Panel

The connectors and controls of all three amplifier types are identical except for the maximum rated output power.

1 - Overload warning
2 - Fault warning
3 - VU-meter, -18, -10, -6, 0, +1dB
4 - Mains switch
5 - Power-on lamp
6 – 24 VDC backup power
7 – Frame ground connection
8 – Mains power connector and fuse
9 – Loudspeaker connections
10 – Pre-warning chime signal control
11 – Master volume control
12 – Master tone controls
13 – Entertainment input and output with volume preset
14 – Call/alarm audio input and output with volume preset
15 – 8 ohm monitor loudspeaker output with volume control
16 – no/nc relay for amplifier fault warning
17 – 24 VDC 800 mA power to external equipment
18 – Remote volume control
19 – Priority over entertainment input

Cabinet

The amplifier is prepared for mounting in a standard 19” rack and will occupy 3HU (133 mm) in height. The amplifier can also be free-standing on a level, open surface. Each amplifier has a built-in cooling fan, the front and back must be kept free of objects in order to secure sufficient air flow.

Power

VPA-120-3.PNG

The amplifiers are powered from 230 or 115 VAC mains, or 24 VDC.
The mains voltage is set inside the amplifier (default setting is 230 V). There is a mains circuit breaker on the cabinet front, and a mains fuse in conjunction with the mains inlet. The fuse value depends on the amplifier type.
24 VDC can be used as a backup source in case of mains power failure. The 24 V backup is not turned off by the mains switch or interrupted in case of a blown mains fuse.
If an accumulator is used as 24 V backup, it will not be charged from the amplifier.
24 VDC/800 mA is available from the amplifier for external equipment.
The amplifier must be grounded either through the earth leg in the mains plug or by a 1.5 mm wire between the amplifier’s ground terminal and proven good grounding point, e.g. the rack frame.
















Signal inputs

VPA-120-4.PNG

There are two inputs with 3-pin XLR connectors:

  • Entertainment (BGM) for background music etc. with separate preset input level control.
  • Call / alarm input for announcements and alarm messages with separate preset input level control.

Both inputs are connected in parallel with signal outputs to slave amplifiers or recorders.
There are common master tone- and volume controls for both inputs. In addition, the volume may be controlled remotely by an external potentiometer.
A call input signal will automatically mute the BGM entertainment source (VOX function). This can also be achieved manually by connecting the microphone switch to the priority terminals.
A pre-warning chime signal can be given in front of a message when a priority switch is pushed. This feature can be switched on/off and the chime loudness can be adjusted.