Syntax
MPP <pager-id> <source.phys.no> <"mail-text"/mail-id> [<beepcode>] [<no-transm>] [<prior>]
- <pager-id> is pager number 1 - 600
- <source.phys.no> is Physical number considered as sender of paging, used for filling in predefined mails. Not used for Free text mails, use 0.
- Mail text: Free text (maximum 16 characters) in quotes, or a Predefined AlphaCom mails number
- <beepcode> : 0-9 Beep code sent to paging system, in record type 3 of ESPA 4.4.4 message.
- <no-transm> : 1, 2.. Number of transmissions, code sent to paging system, in record type 5 of ESPA 4.4.4 message.
- <prior> : 1 , 2 or 3: Priority sent to paging system, in record type 6 of ESPA 4.4.4. 1 = Alarm; 2 = High; 3 = Normal
Example
MPP 2 0 “Temp. alarm” – Send text-message to pager 2