PrisCom station - Configuration
From Zenitel Wiki
Contents
Minimun software requirements
- AMC software v.9.09 or later
- AlphaPro 9.21 or later
Start point options
The station properties are programmed from AlphaPro
- Basic features: Start with a new AlphaPro database and fill in all parameters from scratch
- Advanced features: Use a preprogrammed AlphaPro database.
Basic feature programming
The 7061 and 7063 uses “Two tone DAK signaling", not regular DAK signaling
- In Users & Stations -> User Preferences set DAK signaling to "(3) Two tone signaling w/ack“
- In Users & Stations -> DAK assign numbers to the panel buttons:
- DAK 2 = Call button
- DAK 3 = Program button (not available on the 100 7061 000)
Advanced feature programming
Copy the PrisCom database to the AlphaPro Database folder. Start AlphaPro and select the PrisCom database.
Guard station configuration
- In Users & Stations -> UDP, include the station in UDP 1
- In Users & Stations -> Group, include the station in a “Guard group”. This is required even with a single guard station
Prison station configuration
- In Users & Stations -> UDP, include the station in UDP 2, and enter the “Guard group” index number in the Used Defined Parameter field. This is the target for calls from this station.
Notes on DAK programming:
- No DAK programming is required
- The event handler programming in the PrisCom database will automatically set “Two tone DAK signaling”, and program the DAK’s to point to physical station 500 and 501
- Physical station 500 and 501 is preconfigured with CellStation DAK keys