2-2b. CCTV with relay - Event Handler (solution)

From Zenitel Wiki

Revision as of 16:04, 27 February 2013 by Asle (talk) (Solution)
System configuration


Solution

CCTV Control:

  • Pressing the call button at the Entrance or in the Elevator should generate a call in private ringing mode to the Main Guard.
Program DAK 1 of the Elevator station to "I 400"


Program DAK 1 of the Entrance station to "I 400"

]]


By setting Call Priority Setup = Low, the call from the Elevator will be forced to Private ringing mode, regardless of the Open/Private status og the Main Guard


By setting Call Priority Setup = Low, the call from the Entrance will be forced to Private ringing mode, regardless of the Open/Private status og the Main Guard


  • A relay output to the CCTV system should be activated when the private ringing starts. There is one relay for each substation, RCO 5 and RCO 6.
  • The relay should stay activate until the call is accepted and the conversation is cancelled. (If the call is not answered, the relay must drop when the ringing times out).